Sonographic diagnosis of catheter malposition in a patient with postoperative plexus lesion after right internal jugular vein catheterization--case report.

نویسندگان

  • Werner Tiefenthaler
  • Gregor K Wenning
  • Hannes Gruber
  • Arnulf Benzer
چکیده

PURPOSE Postoperative brachial plexus lesion has been reported only rarely after catheterization of the right internal jugular vein (RIJV), and then is usually considered to be the result of puncture hematoma. CLINICAL FEATURES We here present the case of plexus brachialis injury after catheterization of the RIJV with ultrasonography showing direct compression of the plexus brachialis by a central venous catheter without evidence of puncture hematoma. CONCLUSION Every case of plexus brachialis injury after catheterization of the RIJV should be followed up by an emergency sonogram to rule out hematoma or catheter malposition. Running head: Sonographic diagnosis of catheter malposition after RIJV catheterization.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A catheter malpositioned patient with pain and paresthesia

We report a 54-year-old woman with the history of end-stage renal disease (ESRD) who was admitted to our hospital because of volume overload. Due to long-term use of peripheral veins and arteriovenous fistula (AVF) failure, central venous catheterization was the only choice for hemodialysis. She developed right upper extremiti’s pain and paresis during hemodialysis. A posteroanterior chest x-ra...

متن کامل

An Uncommon Cause of Contralateral Brachial Plexus Injury Following Jugular Venous Cannulation

BACKGROUND The complication rate of central venous catheterization ranges from 4% to 35%. Brachial plexus injury can occur, mostly on the same side as the catheterization, without affecting the contralateral brachial plexus. CASE REPORT A 71-year-old woman received placement of a vein hemodialysis catheter via right internal jugular vein. Five days after the cannulation, she complained of contr...

متن کامل

Malposition of central venous catheter in the left internal jugular vein--a case report.

Malposition of central venous catheter is a complication of central venous catheterization. A case of left internal jugular catheterization via left external jugular vein is reported. Details of the procedure are described and the literature is reviewed for similar malpositions.

متن کامل

Malposition of subclavian vein catheter inserted through indirect technique in a pediatric liver transplantation: a case report

INTRODUCTION Clinicians use either direct or indirect (Seldinger) techniques for internal juguler or subclavian vein catheterization. This report aims to point out that the success rate of the direct technique where the catheter is inserted directly through the cannula may be higher particularly in catheterization of pediatric cases. CASE PRESENTATION A 7.5-month-old female infant weighing 72...

متن کامل

The malposition of a central venous catheter through a sheath introducer via the left internal jugular vein

RATIONALE The misplacement of central venous catheter (CVC) can occur more often at the left jugular vein than the right side due to anatomic differences. And many of the previously reported cases are about catheter misplacement resulting from vessel penetration associated with guidewire. This case differs that the catheter itself through the sheath introducer can cause venous injury that may l...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Middle East journal of anaesthesiology

دوره 20 3  شماره 

صفحات  -

تاریخ انتشار 2009