Simulation of Tree Shade Impacts on Residential Energy Use for Space Conditioning in Sacramento

نویسندگان

  • J R Simpson
  • E G Mcpherson
چکیده

-Tree shade reduces summer air conditioning demand and increases winter heating load by intercepting solar energy that would otherwise heat the shaded structure. We evaluate the magnitude of these effects here for 254 residential properties participating in a utility sponsored tree planting program in Sacramento, California. Tree and building characteristics and typical weather data are used to model hourly shading and energy used for space conditioning for each building for a period of one year. There were an average of 3.1 program trees per property which reduced annual and peak (8 h average from 1 to 9 p.m. Pacific Daylight Time) cooling energy use 153 kWh (7.1%) and 0.08 kW (2.3 %) per tree, respectively. Annual heating load increased 0.85 GJ (0.80 MBtu, 1.9%) per tree. Changes in cooling load were smaller, but percentage changes larger, for newer buildings. Averaged over all homes, annual cooling savings of $15.25 per tree were reduced by a heating penalty of $5.25 per tree, for net savings of $10.00 per tree from shade. We estimate an annual cooling penalty of $2.80 per tree and heating savings of $6.80 per tree from reduced wind speed, for a net savings of $4.00 per tree, and total annual savings of $14.00 per tree ($43.00 per property). Results are found to be consistent with previous simulations and the limited measurements available. Published by Elsevier Science Ltd. Key word index: Air conditioning, tree planting, tree shade, urban forest.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved Estimates of Tree-shade Effects on Residential Energy Use

Tree-shade alters building cooling and heating loads by reducing incident solar radiation. Estimates of the magnitude of this effect, and how it is in¯uenced by urban forest structure (e.g. tree size and location), are dif®cult due to the complexity inherent in tree±sun±building interactions. The objective of this paper is to present a simpli®ed method for making these estimates appropriate for...

متن کامل

Impact of Shade on Hvac Energy Consumption in Buildings: a Residential Case Study

The impact of shade on the heating, ventilation, and air conditioning (HVAC) energy consumption in buildings is not automatically included in whole building energy simulations. Using transient system simulation (TRNSYS) software, models of the Union County Housing Authority’s energy efficient duplex enable the calculation of a monetary value for shading from trees, adjacent buildings, or shade ...

متن کامل

Potentials of Vernacular Climatic Solutions (VCS) in Energy Efficiency of Domestic Buildings in Hot and Humid Climate: The Case Study of Bushehr, Iran

This study aims to use vernacular climatic solutions (VCS) of traditional dwellings of Bushehr in common residential buildings of this city in southern Iran and answer to the question that “What is the effect of VCS in terms of energy consumption in these buildings?”. This research was conducted on two levels. At the first level, after selecting an existing model of common residential buildings...

متن کامل

Shade trees reduce building energy use and CO2 emissions from power plants.

Urban shade trees offer significant benefits in reducing building air-conditioning demand and improving urban air quality by reducing smog. The savings associated with these benefits vary by climate region and can be up to $200 per tree. The cost of planting trees and maintaining them can vary from $10 to $500 per tree. Tree-planting programs can be designed to have lower costs so that they off...

متن کامل

Performance Study of a Solar Integrated Central Heating System of a Residential Building Using Trnsys- an Hourly Simulation Model (RESEARCH NOTE)

In this investigation, the performance of an existing heating system of a residential building incorporated with an array of solar thermal collectors was studied. For this purpose, transient systems simulation program model was assembled to estimate the hour-by-hour performance of the existing and the system equipped with the solar thermal collectors in terms of the provided space air condition...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -