Scanning electron microscopy analysis of luminal inflammation induced by different types of coronary stent in an animal model.

نویسندگان

  • Armando Pérez de Prado
  • Claudia Pérez-Martínez
  • Carlos Cuellas-Ramón
  • José M Gonzalo-Orden
  • Marta Regueiro-Purriños
  • Beatriz Martínez-Fernández
  • Alejandro Diego-Nieto
  • Felipe Fernández-Vázquez
چکیده

There is histological evidence that drug-eluting stents are associated with delayed endothelialization and a persistent inflammatory state. Moreover, clusters of inflammatory cells have been observed on luminal surfaces by scanning electron microscopy. With the aim of quantifying this inflammatory response, we implanted one bare-metal stent and two drug-eluting stents containing different doses of vinblastine embedded in the same polymer into the coronary arteries of 12 domestic pigs. The density of inflammatory cells in a representative area (100 x 100 μm) was quantified at 3 and 7 days. Endothelialization was more complete in bare-metal stents than in drug-eluting stents at both 3 days (P=.016) and 7 days (P=.0001). The degree of inflammation induced by the drug-eluting stents was higher than that induced by the bare-metal stents at both 3 days (11.8±3.5% vs. 4.5±2%; P=.001) and 7 days (26.3±4.4% vs. 1.2±1.5%; P=.0001). In addition, the time sequence was inverted: the inflammatory response increased over time with the drug-eluting stents, while the opposite occurred with the bare-metal stents.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Adjuvant therapy for intracoronary stents. Investigations in atherosclerotic swine.

Early thrombosis has complicated human stent implantation in several trials. To determine the best anticoagulation/antiplatelet therapy to maintain stent patency after percutaneous transluminal coronary angioplasty, we implanted the flexible balloon-expandable coil stent into the left anterior descending coronary artery of 28 atherosclerotic 8-month-old Hanford miniature swine. Animals were ran...

متن کامل

Nanoporous CREG-Eluting Stent Attenuates In-Stent Neointimal Formation in Porcine Coronary Arteries

BACKGROUND The goal of this study was to evaluate the efficacy of a nanoporous CREG-eluting stent (CREGES) in inhibiting neointimal formation in a porcine coronary model. METHODS In vitro proliferation assays were performed using isolated human endothelial and smooth muscle cells to investigate the cell-specific pharmacokinetic effects of CREG and sirolimus. We implanted CREGES, control sirol...

متن کامل

Effectiveness of statin-eluting stent on early inflammatory response and neointimal thickness in a porcine coronary model.

BACKGROUND Drug-eluting stent (DES) implantation is routine during coronary revascularization because DES significantly reduce rates of restenosis and target lesion revascularization compared with bare metal stent (BMS). However, available DES have limitations, such as late thrombosis because of delayed healing with poorer endothelialization and persistent local inflammation. Statins can inhibi...

متن کامل

Fabrication of Spiral Stent with Superelastic/ Shape Memory Nitinol Alloy for Femoral Vessel

Stent is a metal mesh tube for opening the obstructed vessels of the body. Ni-Ti alloy is a suitable metal for fabrication of stent due to its potential for applying the appropriate stress and strain to the vessel walls. In this study, super-elastic Nitinol wire was used to build stent samples usable to open femoral vessel. Ageing was performed at 500°C for different periods of time to determin...

متن کامل

Bile Flow Phantom Model and Animal Bile Duct Dilation Model for Evaluating Biliary Plastic Stents with Advanced Hydrophilic Coating

BACKGROUND/AIMS The efforts to improve biliary plastic stents (PSs) for decreasing biofilm formation and overcome short patency time have been continued. The aim of this study is to evaluate the effect of advanced hydrophilic coating for patency and biodurability of PS. METHODS Using an in vitro bile flow phantom model, we compared patency between prototype PS with hydrophilic coating (PS+HC)...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista espanola de cardiologia

دوره 64 2  شماره 

صفحات  -

تاریخ انتشار 2011