Ultrafast high-pressure AC electro-osmotic pumps for portable biomedical microfluidics.

نویسندگان

  • Chien-Chih Huang
  • Martin Z Bazant
  • Todd Thorsen
چکیده

This paper details the development of an integrated AC electro-osmotic (ACEO) microfluidic pump for dilute electrolytes consisting of a long serpentine microchannel lined with three dimensional (3D) stepped electrode arrays. Using low AC voltage (1 V rms, 1 kHz), power (5 mW) and current (4.5 mA) in water, the pump is capable of generating a 1.3 kPa head pressure, a 100-fold increase over prior ACEO pumps, and a 1.3 mm/s effective slip velocity over the electrodes without flow reversal. The integrated ACEO pump can utilize low ionic strength solutions such as distilled water as the working solution to pump physiological strength (100 mM) biological solutions in separate microfluidic devices, with potential applications in portable or implantable biomedical microfluidic devices. As a proof-of-concept experiment, the use of the ACEO pumps for DNA hybridization in a microfluidic microarray is demonstrated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Theoretical prediction of fast 3D AC electro-osmotic pumps.

AC electro-osmotic (ACEO) pumps in microfluidics currently involve planar electrode arrays, but recent work on the underlying phenomenon of induced-charge electro-osmosis (ICEO) suggests that three-dimensional (3D) geometries may be exploited to achieve faster flows. In this paper, we present some new design principles for periodic 3D ACEO pumps, such as the "fluid conveyor belt" of ICEO flow o...

متن کامل

Experimental Study of Electrolyte Dependence of Ac Electroosmotic Pumps

Recent studies indicate increased efficiency of microfluidic ac electro-osmotic pumps by utilizing broken symmetries with raised steps on the electrodes. An experimental study on the dependence of ac electroosmosis in microchannels on solution chemistry for the new fast aceo stepped pumps is reported. Micro PIV was used to determine peak velocities for M mM ! " concentrations of KCl, NaCl, CaCl...

متن کامل

The effect of step height on the performance of three-dimensional ac electro-osmotic microfluidic pumps.

Recent numerical and experimental studies have investigated the increase in efficiency of microfluidic ac electro-osmotic pumps by introducing nonplanar geometries with raised steps on the electrodes. In this study, we analyze the effect of the step height on ac electro-osmotic pump performance. AC electro-osmotic pumps with three-dimensional electroplated steps are fabricated on glass substrat...

متن کامل

A new electro-osmotic pump based on silica monoliths

A high-pressure electro-osmotic (EO) micro-pump fabricated by a sol–gel process is shown to be potentially effective as a fluid-driving unit on chip-scale analytical systems. A silica monolithic matrix with a morphology of micron-scaled through pores was synthesized within the 100 m inner diameter (i.d.) fused-silica capillary of the micro-pump. The monolith bonds directly with the capillary wa...

متن کامل

Design principle for improved three-dimensional ac electro-osmotic pumps.

Three-dimensional (3D) ac electro-osmotic (ACEO) pumps have recently been developed that are much faster and more robust than previous planar designs. The basic idea is to create a "fluid conveyor belt" by placing opposing ACEO slip velocities at different heights. Current designs involve electrodes with electroplated steps, whose heights have been optimized in simulations and experiments. Here...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lab on a chip

دوره 10 1  شماره 

صفحات  -

تاریخ انتشار 2010