Application of the N-point moving average method for brachial pressure waveform-derived estimation of central aortic systolic pressure.

نویسندگان

  • Yuan-Ta Shih
  • Hao-Min Cheng
  • Shih-Hsien Sung
  • Wei-Chih Hu
  • Chen-Huan Chen
چکیده

The N-point moving average (NPMA) is a mathematical low-pass filter that can smooth peaked noninvasively acquired radial pressure waveforms to estimate central aortic systolic pressure using a common denominator of N/4 (where N=the acquisition sampling frequency). The present study investigated whether the NPMA method can be applied to brachial pressure waveforms. In the derivation group, simultaneously recorded invasive high-fidelity brachial and central aortic pressure waveforms from 40 subjects were analyzed to identify the best common denominator. In the validation group, the NPMA method with the obtained common denominator was applied on noninvasive brachial pressure waveforms of 100 subjects. Validity was tested by comparing the noninvasive with the simultaneously recorded invasive central aortic systolic pressure. Noninvasive brachial pressure waveforms were calibrated to the cuff systolic and diastolic blood pressures. In the derivation study, an optimal denominator of N/6 was identified for NPMA to derive central aortic systolic pressure. The mean difference between the invasively/noninvasively estimated (N/6) and invasively measured central aortic systolic pressure was 0.1±3.5 and -0.6±7.6 mm Hg in the derivation and validation study, respectively. It satisfied the Association for the Advancement of Medical Instrumentation standard of 5±8 mm Hg. In conclusion, this method for estimating central aortic systolic pressure using either invasive or noninvasive brachial pressure waves requires a common denominator of N/6. By integrating the NPMA method into the ordinary oscillometric blood pressure determining process, convenient noninvasive central aortic systolic pressure values could be obtained with acceptable accuracy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Central Blood Pressure/Aortic Stiffness Validation of a Brachial Cuff-Based Method for Estimating Central Systolic Blood Pressure

The prognostic value of central systolic blood pressure has been established recently. At present, its noninvasive assessment is limited by the need of dedicated equipment and trained operators. Moreover, ambulatory and home blood pressure monitoring of central pressures are not feasible. An algorithm enabling conventional automated oscillometric blood pressure monitors to assess central systol...

متن کامل

Effect of non-invasive calibration of radial waveforms on error in transfer-function-derived central aortic waveform characteristics.

Transfer function techniques are increasingly used for non-invasive estimation of central aortic waveform characteristics. Non-invasive radial waveforms must be calibrated for this purpose. Most validation studies have used invasive pressures for calibration, with little data on the impact of non-invasive calibration on transfer-function-derived aortic waveform characteristics. In the present s...

متن کامل

Central Blood Pressure Brachial Blood Pressure–Independent Relations Between Radial Late Systolic Shoulder-Derived Aortic Pressures and Target Organ Changes

Central aortic blood pressure (BP; BPc) predicts outcomes beyond brachial BP. In this regard, the application of a generalized transfer function (GTF) to radial pulse waves for the derivation of BPc is an easy and reproducible measurement technique. However, the use of the GTF may not be appropriate in all circumstances. Although the peak of the second shoulder of the radial waveform (P2) is cl...

متن کامل

Impact of radial artery pressure waveform calibration on estimated central pressure using a transfer function approach.

Impact of Radial Artery Pressure Waveform Calibration on Estimated Central Pressure Using a Transfer Function Approach To the Editor: It is with great interest that we have read the excellent work of McEniery et al1 on the variability of the relation between central and brachial pulse pressure (pressure amplification), assessed in 10 000 subjects. We were, however, a little surprised about the ...

متن کامل

Acute effects of cold exposure on central aortic wave reflection.

The purpose of this study was to determine the effects of acute cold exposure on the timing and amplitude of central aortic wave reflection and central pressure. We hypothesized that cold exposure would result in an early return of reflected pressure waves from the periphery and an increase in central aortic systolic pressure as a result of cold-induced vasoconstriction. Twelve apparently healt...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Hypertension

دوره 63 4  شماره 

صفحات  -

تاریخ انتشار 2014