On the Respiratory Mechanics Measured by Forced Oscillation Technique in Patients with Systemic Sclerosis
نویسندگان
چکیده
BACKGROUND Pulmonary complications are the most common cause of death and morbidity in systemic sclerosis (SSc). The forced oscillation technique (FOT) offers a simple and detailed approach to investigate the mechanical properties of the respiratory system. We hypothesized that SSc may introduce changes in the resistive and reactive properties of the respiratory system, and that FOT may help the diagnosis of these abnormalities. METHODOLOGY/PRINCIPAL FINDINGS We tested these hypotheses in controls (n = 30) and patients with abnormalities classified using spirometry (n = 52) and pulmonary volumes (n = 29). Resistive data were interpreted with the zero-intercept resistance (Ri) and the slope of the resistance (S) as a function of frequency. Reactance changes were evaluated by the mean reactance between 4 and 32 Hz (Xm) and the dynamic compliance (Crs,dyn). The mechanical load was evaluated using the absolute value of the impedance in 4 Hz (Z4Hz). A compartmental model was used to obtain central (R) and peripheral (Rp) resistances, and alveolar compliance (C). The clinical usefulness was evaluated by investigating the area under the receiver operating characteristic curve (AUC). The presence of expiratory flow limitation (EFL) was also evaluated. For the groups classified using spirometry, SSc resulted in increased values in Ri, R, Rp and Z4Hz (p<0.003) and reductions in Crs,dyn, C and Xm (p<0.004). Z4Hz, C and Crs,dyn exhibited a high diagnostic accuracy (AUC>0.90). In groups classified by pulmonary volume, SSc resulted in reductions in S, Xm, C and Crs,dyn (p<0.01). Xm, C and Crs,dyn exhibited adequate diagnostic accuracy (AUC>0.80). It was also observed that EFL is not common in patients with SSc. CONCLUSIONS/SIGNIFICANCE This study provides evidence that the respiratory resistance and reactance are changed in SSc. This analysis provides a useful description that is of particular significance for understanding respiratory pathophysiology and to ease the diagnosis of respiratory abnormalities in these patients.
منابع مشابه
The forced oscillation technique in clinical practice: methodology, recommendations and future developments.
The forced oscillation technique (FOT) is a noninvasive method with which to measure respiratory mechanics. FOT employs small-amplitude pressure oscillations superimposed on the normal breathing and therefore has the advantage over conventional lung function techniques that it does not require the performance of respiratory manoeuvres. The present European Respiratory Society Task Force Report ...
متن کاملWithin-Breath Analysis of Respiratory Mechanics in Asthmatic Patients by Forced Oscillation
INTRODUCTION The within-breath analysis of respiratory mechanics by the monofrequency Forced Oscillation Technique (mFOT) is of great interest in both physiopathology studies and the diagnosis of respiratory diseases. However, there are limited data on the use of this technique in the analysis of asthma. This study evaluates within-breath mechanics of asthmatic individuals and the contribution ...
متن کاملA portable forced oscillation device for respiratory home monitoring.
The increase in the prevalence of chronic respiratory diseases has resulted in a rise in health services provided at home. The forced oscillation technique (FOT) proves to be a useful tool when it is desired to assess lung function noninvasively, and particularly for patients in whom spirometry cannot be applied. As no portable FOT device is currently available, the aim of this study was to des...
متن کاملServocontrolled generator to measure respiratory impedance from 0.25 to 26 Hz in ventilated patients at different PEEP levels.
Assessing respiratory impedance (Zrs) in ventilated patients over a wide frequency band, ranging from breathing rates to typical forced oscillation frequencies, during end-expiratory pauses at different positive end-expiratory pressures (PEEP) is of potential interest to assess a patient's respiratory mechanics. Zrs measurements under these conditions are not possible with the present variants ...
متن کاملRespiratory mechanics in ventilated COPD patients: forced oscillation versus occlusion techniques.
The respiratory mechanics of artificially ventilated chronic obstructive pulmonary disease (COPD) patients were investigated by means of the forced oscillation (FOT) and the end-inspiratory airway occlusion (AOT) techniques. FOT was applied to measure respiratory resistance (Rrs) and reactance (Xrs) from 0.25-16 Hz. Maximum (Rmax) and minimum (Rmin) resistances, static elastance (Est) and time ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 8 شماره
صفحات -
تاریخ انتشار 2013