WFC3 Thermal Vacuum Testing: UVIS Crosstalk

نویسنده

  • S. Baggett
چکیده

The integrated WFC3 instrument recently underwent testing under thermal vacuum (TV) conditions in the GSFC SES (Goddard Space Flight Center Space Environment Simulator). This report summarizes the behavior of the UVIS channel crosstalk features seen in the TV data as compared to the behavior seen in previous data taken under ambient conditions in early 2004 and provides an update on the hardware investigation underway at the Detector Characterization Lab (DCL) at GSFC . The crosstalk in the TV images has been found to be essentially identical to the crosstalk in ambient images: 1) levels are low, +/a few DN on average though individual pixels can exhibit crosstalk up to +/-10DN, 2) the effect is highly nonlinear, 3) the crosstalk is bias and gain dependent, and 4) the behavior of the crosstalk as a function of binning and readout combination remains unchanged. The hardware testing at DCL has found that the CEB test set and the flight-like harness generate crosstalk which does not behave exactly like the crosstalk in the flight channel. Further investigation into the cause of the crosstalk will require use of the flight hardware.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

WFC3 TV3 Testing: System Throughput on the UVIS Build 1’ Detector

The UVIS flight detector (UVIS build 1’) was installed in WFC3 prior to its third and final campaign of thermal vacuum ground testing. We performed testing of the end-to-end system throughput on the UVIS channel, and found that it performs near or better than expectations at most wavelengths. However, the measured throughput is significantly different than that measured for this detector in the...

متن کامل

WFC3 Ambient Testing: UVIS Dark Current Rate

Ground testing of WFC3 under ambient conditions during April of 2007 was performed in order to prepare for upcoming thermal vacuum testing. As a part of this ambient testing, the dark current rate of the spare UVIS package (UVIS build 2) was measured while the CCD was operating at a temperature of -54oC. This temperature is significantly higher than the nominal operating temperature of -83oC, l...

متن کامل

WFC3 Flight Detector Alignment Characterization in Thermal-Vacuum Test #1

We have performed an initial assessment of the alignment status of the UVIS-1and IR-2 flight detectors as mounted in WFC3 during the first instrument-level thermal-vac test. Both detectors are found to be aligned out of tolerance, indicating errors in the transfer of surrogate alignment information to the flight articles. Measurements made at various times through the thermal vac test, with the...

متن کامل

WFC3 TV2 Testing: Image Stability

ABSTRACT I review the image stability tests performed during the second thermal-vacuum (TV) campaign of WFC3. In the first TV campaign, significant drifts were seen in both channels in response to induced thermal changes in the instrument, but subsequent analysis indicated that the induced temperature variations were unrealistically large (compared to on-orbit conditions). In the current tests,...

متن کامل

The Photometric Performance and Calibration of WFC3

We analyze multiple observations of five bright HST spectrophotometric standard stars obtained with WFC3/UVIS and WFC3/IR in order to establish the temporal stability of the instrument over its first year of science operations and its photometric sensitivity. Observations of the five stars, GD 153, G191B2B, GD 71, GRW+70d5824, and P330E were obtained at multiple dither positions at each epoch i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005