The use of Fuller's earth to reduce acetoacetate interference in the measurement of serum creatinine by the Beckman Astra-4 analyser

نویسنده

  • John Thompson
چکیده

Several authors have recently re-emphasized the positive interference of acetoacetate in the measurement of creatinine using the Jaff6 reaction [1-3]. On theoretical grounds, the measurement of creatinine in the presence of acetoacetate should be possible using a kinetic method [4]. In practice, however, measurements by some instruments employing a kinetic Jaff6 method suffer from marked interference by acetoacetate. Haekel described a procedure for the measurement of creatinine in the presence of acetoacetate, utilizing the adsorption of creatinine onto Fuller’s earth, and subsequent simultaneous elution and colour development with alkaline picrate [-5 and 6]. One of the variations of his procedure is that it omits a protein precipitation step [5]. In the present work, the procedure omitting a protein precipitation step has been adapted by eluting creatinine from the Fuller’s earth and measuring the creatinine in the eluate using a Beckman Astra-4 analyser (Beckman RIIC Ltd, High Wycombe, Buckinghamshire HP12 3NR, UK).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An automated dry-slide enzymatic method evaluated for measurement of creatinine in serum.

We evaluated an automated dry-slide enzymatic method involving creatinine iminohydrolase for measurement of creatinine in serum with the Kodak Ektachem analyzer. The means (and SD) for three commercially available quality-control sera, analyzed during eight weeks, were 9.7 (1.0), 16.6 (0.9), and 61 (2.1) mg/L. The regression equation for 105 samples measured with the Technicon SMAC (x) and Ekta...

متن کامل

Notes for Contributors

had been unused for some time within the calibration period could give erroneously low results. This was most likely to happen if a series of urine samples were analysed followed by a serum, but the .effect was by no means reproducible. The manufacturer is aware of this problem, which is probably caused by deterioration of the reagent in the measuring cup, and is taking steps to correct it. Cre...

متن کامل

Evaluation of the Beckman creatinine analyzer.

We compared results obtained with the Beckman Creatinine Analyzer (Beckman Instruments, Inc.) to those with the GEMSAEC Centrifugal Analyzer (Electro-Nucleonics, Inc.) and with a manual method for determination of creatinine in serum and urine. Linearity, stability, recovery, and precision were evaluated. Interference from bilirubin, protein, lipemia, uric acid, and hemolysis is negligible, but...

متن کامل

Measurement of urinary constituents with the Astra-8 Multichannel Analyzer.

The Beckman Astra-8 is a computerized, discrete-microsample, multiple-test clinical chemistry analyzer. We have examined its capability to measure urine Na+, K+, Cl-, urea nitrogen, glucose, and creatinine and found that (a) the Astra measurements are linear, accurate, and precise in concentration ranges of urine analytes; (b) urine analyte concentrations measured with the Astra correlate well ...

متن کامل

Lactulose interferes in the alkaline picrate assay for creatinine.

Errors of more than 10 mg/L in measured serum creatinine concentrations were encountered for an azotemic patient who was given lactulose orally. The magnitude of the apparent error fluctuated with the dose of lactulose. Additions of lactulose to serum produced a linear increase in the creatinine measured by each of two automated methods that involve use of the alkaline picrate (Jaffé) reaction....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of Automatic Chemistry

دوره 4  شماره 

صفحات  -

تاریخ انتشار 1982