Actual performance of mechanical ventilators in ICU: a multicentric quality control study

نویسندگان

  • Leonardo Govoni
  • Raffaele L Dellaca’
  • Oscar Peñuelas
  • Giacomo Bellani
  • Antonio Artigas
  • Miquel Ferrer
  • Daniel Navajas
  • Antonio Pedotti
  • Ramon Farré
چکیده

Even if the performance of a given ventilator has been evaluated in the laboratory under very well controlled conditions, inappropriate maintenance and lack of long-term stability and accuracy of the ventilator sensors may lead to ventilation errors in actual clinical practice. The aim of this study was to evaluate the actual performances of ventilators during clinical routines. A resistance (7.69 cmH(2)O/L/s) - elastance (100 mL/cmH(2)O) test lung equipped with pressure, flow, and oxygen concentration sensors was connected to the Y-piece of all the mechanical ventilators available for patients in four intensive care units (ICUs; n = 66). Ventilators were set to volume-controlled ventilation with tidal volume = 600 mL, respiratory rate = 20 breaths/minute, positive end-expiratory pressure (PEEP) = 8 cmH(2)O, and oxygen fraction = 0.5. The signals from the sensors were recorded to compute the ventilation parameters. The average ± standard deviation and range (min-max) of the ventilatory parameters were the following: inspired tidal volume = 607 ± 36 (530-723) mL, expired tidal volume = 608 ± 36 (530-728) mL, peak pressure = 20.8 ± 2.3 (17.2-25.9) cmH(2)O, respiratory rate = 20.09 ± 0.35 (19.5-21.6) breaths/minute, PEEP = 8.43 ± 0.57 (7.26-10.8) cmH(2)O, oxygen fraction = 0.49 ± 0.014 (0.41-0.53). The more error-prone parameters were the ones related to the measure of flow. In several cases, the actual delivered mechanical ventilation was considerably different from the set one, suggesting the need for improving quality control procedures for these machines.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance of mechanical ventilators at the patient's home: a multicentre quality control study.

BACKGROUND Quality control procedures vary considerably among the providers of equipment for home mechanical ventilation (HMV). METHODS A multicentre quality control survey of HMV was performed at the home of 300 patients included in the HMV programmes of four hospitals in Barcelona. It consisted of three steps: (1) the prescribed ventilation settings, the actual settings in the ventilator co...

متن کامل

ASSISTED VENTILATION Performance of mechanical ventilators at the patient’s home: a multicentre quality control study

Background: Quality control procedures vary considerably among the providers of equipment for home mechanical ventilation (HMV). Methods: A multicentre quality control survey of HMV was performed at the home of 300 patients included in the HMV programmes of four hospitals in Barcelona. It consisted of three steps: (1) the prescribed ventilation settings, the actual settings in the ventilator co...

متن کامل

استفاده همزمان از دو ونتیلاتور برای درمان عوارض ریوی ناشی از تهویه مکانیکی در بیمار مولتیپل تروما: گزارش مورد

Background and Objective: Some of multiple trauma patients admitted in ICU (Intensive Care Unit) are intubated and ventilated by mechanical ventilation. These patients are prone to many complications such as lung disease. Reasons for this complication are patients without any movement, incomplete cough reflex, GI aspiration and then not a good pulmonary discharge prone the lungs of patients to ...

متن کامل

The mechanical ventilator: past, present, and future.

The use of ventilatory assistance can be traced back to biblical times. However, mechanical ventilators, in the form of negative-pressure ventilation, first appeared in the early 1800s. Positive-pressure devices started to become available around 1900 and today's typical intensive care unit (ICU) ventilator did not begin to be developed until the 1940s. From the original 1940s ventilators until...

متن کامل

Near-infrared spectroscopy with vascular occlusion test may not be the adequate tool to explore microcirculation in pulmonary arterial hypertension.

essentials of respiratory care, 4th edition. St. Louis:Mosby Elsevier; 2005:103. 13. L’Her E, Roy A. Bench tests of simple, handy ventilators for pandemics: performance, autonomy, and ergonomy. Respir Care 2011;56(6):751-760. 14. Lyazidi A, Thille AW, Carteaux G, Galia F, Brochard L, Richard JC. Bench test evaluation of volume delivered by modern ICU ventilators during volume-controlled ventila...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2012