Validation of body fat measurement by skinfolds and two bioelectric impedance methods with DEXA--the Chennai Urban Rural Epidemiology Study [CURES-3].

نویسندگان

  • Sudha Vasudev
  • Anjana Mohan
  • Deepa Mohan
  • S Farooq
  • Deepa Raj
  • V Mohan
چکیده

BACKGROUND AND OBJECTIVE Although Asian Indians have been shown to have increased body fat compared to Europeans, there have been very few studies in Asian Indians validating the various methods available for body fat measurement. The aim of this study was to test the validity of body fat measured by two commercial impedance analyzers (leg-to-leg and hand-held) as well as by skinfolds with Dual Energy X-ray Absorptiometry (DEXA) as the reference method in a population based study in southern India. METHODS Body fat percentage (BF%) was measured in 162 South Indian urban men (n=76) and women (n=86) randomly selected from the "Chennai Urban Rural Epidemiology Study" (CURES), an ongoing population based study of a representative population of Chennai. The mean age of the subjects was 45.1 +/- 9.0 years and the body mass index ranged from 16.4 - 34.4 kg/m2. Percentage body fat was measured using DEXA, segmental impedance (leg-to-leg: BF%IMP-LEG; and hand-held BF%IMP-HAND) using the manufacturer's software and skinfolds using the prediction equation from the literature (BF%SKFD). RESULTS Body fat (%) determined by the leg-to-leg method (BF%IMP-LEG 35.10 +/- 7.26) and the skinfolds (BF%SKFD 35.77 +/- 6.06) did not differ significantly from the reference method DEXA (BF%DEXA 35.82 +/- 8.33), but the hand-held impedance method (BF%IMP-HAND 31.38 +/- 6.24) showed significant difference (p < 0.001). The bias for estimation of body fat (%) for the bioimpedance leg-to-leg, hand-held and skinfolds were 0.73 +/- 5.70, 4.45 +/- 4.83 and 0.06 +/- 5.86 respectively. All the three methods showed a fairly good correlation with DEXA (BF%IMP-LEG: r = 0.741, p<0.001; BF%IMP-HAND: r = 0.817, p< 0.001; BF%SKFD: r 0.710, p< 0.001). CONCLUSION The study shows that in urban south Indians, measurement of body fat by the leg-to-leg impedance and the skinfold method have better agreement (lower bias) with DEXA than the hand-held impedance. However, all three methods (skinfolds, the leg-to-leg bioelectric impedance and hand-held impedance) show a fairly good correlation with DEXA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of bioelectrical impedance for the prediction of fat-free mass in Brazilian elderly subjects.

Aging involves both nutritional and physiological changes, reducing fat-free mass (FFM) and increasing body fat, both of which are associated with physical weakness, unfitness and morbidity among the elderly. This study was undertaken to analyze the cross-validity of bioelectrical impedance equations for the prediction of fat-free mass (FFM) in elderly Brazilians. A cross-sectional population-b...

متن کامل

Comparison of body compositional indices assessed by underwater weighing, bioelectrical impedance and anthropometry in Indonesian adolescent girls.

OBJECTIVE To investigate the accuracy of bioelectric impedance analysis and anthropometry to assess percentage body fat (BF %) against underwater weighing (UW). DESIGN AND METHODS A cross sectional study, 102 girls, aged 11-15, were recruited from two Junior High Schools in Jakarta. MEASUREMENTS Measurements of percent-age body fat (BF%) using underwater weighing (UW), bioelectrical impedan...

متن کامل

Bedside methods versus dual energy X-ray absorptiometry for body composition measurement in COPD.

The measurement of body composition is of value in the nutritional assessment of patients with chronic obstructive pulmonary disease (COPD). The purpose of the present study was to compare two bedside methods for the measurement of body composition using dual energy X-ray absorptiometry (DEXA) as a reference method. Fat-free mass (FFM) was measured using DEXA, bioelectric impedance analysis (BI...

متن کامل

Validity of Bioelectrical Impedance Measurement in Predicting Fat-Free Mass of Chinese Children and Adolescents

BACKGROUND The current study aimed to examine the validity of various published bioelectrical impedance analysis (BIA) equations in estimating FFM among Chinese children and adolescents and to develop BIA equations for the estimation of fat-free mass (FFM) appropriate for Chinese children and adolescents. MATERIAL/METHODS A total of 255 healthy Chinese children and adolescents aged 9 to 19 ye...

متن کامل

A comparison of skinfolds and leg-to-leg bioelectrical impedance for the assessment of body composition in children

BACKGROUND: This field-based investigation examined the congruence between skinfolds and bioelectrical impedance in assessing body composition in children. METHODS: Subjects were 162 female and 160 male children 10-15 years of age. Skinfold measures obtained at the triceps and medial calf and a leg-to-leg bioelectrical impedance system were used to determine percent fat using child-specific equ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of the Association of Physicians of India

دوره 52  شماره 

صفحات  -

تاریخ انتشار 2004