Functional field score: the effect of using a Goldmann V-4e isopter instead of a Goldmann III-4e isopter.
نویسندگان
چکیده
PURPOSE To investigate the underestimation of field loss in functional field score (FFS) between the Goldmann isopters III-4e and V-4e in visually impaired patients, in order to develop a predictive model for the FFS(III-4e) based on FFS(v-4e) that adjusts for possible confounders. Although the visual field is generally evaluated using Goldmann isopter III-4e, it has the disadvantage that not all low-vision patients are able to see the stimulus corresponding to this isopter. METHODS Goldmann visual fields were obtained from 58 patients with a variety of eye diseases. Eligibility criteria were age of 18 years or older and valid results of a Goldmann III-4e and V-4e visual field test in at least one eye. Linear regression was used to develop the model, setting FFS(III-4e) as the dependent variable and FFS(V-4e) as the independent one. RESULTS The FFS(V-4e) was higher than the FFS(III-4e), the mean difference being 14.56 points (95% CI, 12.48 -16.64). Multiple linear regression analysis showed that age, functional acuity score, primary eye disease, and central-peripheral loss were not confounders for the prediction of FFS(III-4e). FFS(III-4e) was estimated with the following equation: FFS(III-4e) = -19.25 + 1.063 x FFS(V-4e). CONCLUSIONS The relationship between FFS(III-4e) and FFS(V-4e) is linear, and the FFS(V-4e) can be used to estimate the FFS(III-4e). In practice, just subtracting 19.25 points of the value of FFS(V-4e) will be sufficient to estimate the value of FFS(III-4e). This model should give confidence about using the bigger isopter for determining the visual impairment of a person by the FFS.
منابع مشابه
Normal Values for the Full Visual Field, Corrected for Age- and Reaction Time, Using Semiautomated Kinetic Testing on the Octopus 900 Perimeter.
PURPOSE To determine normal values of the visual field (VF), corrected for age and reaction time (RT) for semiautomated kinetic perimetry (SKP) on the Octopus 900 perimeter, create a model describing the age-dependency of these values, and assess test-retest reliability for each isopter. METHODS Eighty-six eyes of 86 ophthalmologically healthy subjects (age 11-79 years, 34 males, 52 females) ...
متن کاملImpact of internal carotid endarterectomy on visual fields: a non-randomised prospective cohort study in Austria
PURPOSE The goal of this study was to determine whether internal carotid endarterectomy is associated with visual field changes. METHODS Between March 2007 and December 2010, a cohort study involved 29 patients with stenosis of the carotid artery. All patients underwent ophthalmoscopy and kinetic visual field examination (Goldmann perimetry) preoperatively and postoperatively. Furthermore, a ...
متن کاملStimulus parameters for goldmann kinetic perimetry in nonorganic visual loss.
OBJECTIVE To investigate the influence of the stimulus parameters on perimetry at various distances and draw conclusions for the clinical exploration of nonorganic visual loss. METHODS Visual field testing using Goldmann kinetic perimetry was performed on 15 healthy volunteers. The I/1e isopter at 33 cm was compared to the I/1e, II/1e and I/2e isopters at 66 cm. The 0/1e isopter at 33 cm was ...
متن کاملVolume of visual field assessed with kinetic perimetry and its application to static perimetry
BACKGROUND The purpose of this study was to quantify the volume of the kinetic visual field with a single unit that accounts for visual field area and differential luminance sensitivity. METHODS Kinetic visual field perimetry was performed with a Goldmann perimeter using I4e, I3e, I2e, and I1e targets. The visual fields of 25 normal volunteers (17 women, eight men) of mean age 33.9 ± 10.1 (ra...
متن کاملValue of tonometry and tonography in the diagnosis of glaucoma.
In a patient with 6/6 vision, the i/i object on the Goldmann perimeter disappears completely in the 70's and the x/2 object dispapears in the 8o's provided there are no lens opacities to accelerate the process. The o/ i disappears much earlier. With the 1/2 it was found that there was much variation between people and the mean isopter was around 280. In some it reached 400 but in others it was ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 47 5 شماره
صفحات -
تاریخ انتشار 2006