Possibilities and limitations of radioimmunoscintigraphy and conventional diagnostic modalities in choroidal melanoma.

نویسندگان

  • D F Schaling
  • J A Oosterhuis
  • M J Jager
  • H Kakebeeke-Kemme
  • E K Pauwels
چکیده

A prospective clinical study to assess the value of immunoscintigraphy with a monoclonal antibody (MoAb) against high molecular weight melanoma associated antigen (225.28S) was performed in 43 patients with choroidal melanoma; in six patients with a lesion suspected of being choroidal melanoma, and in seven patients with a benign lesion simulating a choroidal melanoma. The results of immunoscintigraphy in choroidal melanoma were compared with results of conventional diagnostic modalities like ultrasonography and fluorescein angiography. Planar scintigraphy showed a detection rate of 49% which is comparable with other studies. The detection with scintigraphy was correlated to the size of the choroidal melanoma. The use of single photon computed tomography did not increase the sensitivity of immunoscintigraphy. Ultrasonography yielded a correct diagnosis in 37 of 42 melanomas (88%). With fluorescein angiography a correct diagnosis was obtained in 11 of 30 melanomas (36.6%). The value of immunoscintigraphy with MoAb 225.28S in small choroidal melanomas is limited; its reliability increases in large tumours. Immunohistochemistry with MoAb 225.28S showed antigen expression in 95% of the stained tissue specimens of choroidal melanoma.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radioimmunoscintigraphy of ocular melanoma with 99mTc labelled cutaneous melanoma antibody fragments.

The possibility of using radiolabelled monoclonal antibody fragments to image uveal melanomas has been assessed in a pilot study. 99mTc labelled F(ab')2 fragments of MoAb 225.28S raised against cutaneous melanomas were used. Initially 10 patients were imaged. In five patients the clinical findings were typical of uveal melanoma. Immunoscintigraphy was positive in all five cases. In a further fi...

متن کامل

Immunoimaging of choroidal melanoma: assessment of its diagnostic accuracy and limitations in 101 cases.

Immunoscintigraphy (IS) was performed on 101 patients with space occupying intraocular lesions including choroidal melanomas (85), choroidal naevi (11), non-melanoma metastases (three), and other melanoma simulating lesions (two). Scintigraphic images with conventional and emission computer tomography techniques were obtained after the intravenous injection of 99mTc-labelled F(ab')2 fragments o...

متن کامل

Quantitative comparison of direct antibody labeling and tumor pretargeting in uveal melanoma.

UNLABELLED SPECT radioimmunoscintigraphy with 99mTc-labeled anti-melanoma monoclonal antibodies (MAbs) 225.28S is being used to detect uveal melanoma. Recently, pretargeting methods have been described to reduce background activity and perform imaging in a shorter time interval. METHODS We compared the three-step pretargeting method with conventional radioimmunoscintigraphy in 15 patients wit...

متن کامل

Radioimmunoscintigraphy and immunohistochemistry with melanoma-associated monoclonal antibodies in choroidal melanoma: a comparison of the clinical and immunohistochemical results.

Radioimmunoscintigraphy with monoclonal antibodies (MoAbs) to melanoma associated antigens is a new technique that can be used as an additional test to detect ocular melanomas in clinically difficult cases. Immunoscintigraphy with 99mtechnetium-labelled monoclonal antibody fragments of MoAb 225.28S in 14 patients with melanoma yielded a positive image in only six cases (43%). The expression of ...

متن کامل

مقایسه دقت فیلمهای Primax و Insight و تصاویر دیجیتالی CMOS-APS در تشخیص پوسیدگی‌های جانبی دندانهای خلفی به صورت آزمایشگاهی

Introduction: Radiography is one of the most important diagnostic methods for evaluation of dental caries. On the other hand, the least amount of radiation along with high quality is a main gold standard. The purpose of this study was to compare the diagnostic accuracy of Primax, Insight Radiographic films, and direct digital images (Schick CMOS-APS), in detection of interproximal natural Carie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 78 4  شماره 

صفحات  -

تاریخ انتشار 1994