Positron emission mammography (PEM): reviewing standardized semiquantitative method
نویسندگان
چکیده
PURPOSE To validate semiquantitative analysis of positron emission mammography (PEM). METHODS Fifty women with histologically confirmed breast lesions were retrospectively enrolled. Semiquantitative uptake values (4 methods), the maximum PEM uptake value (PUVmax), and the lesion-to-background (LTB) value (3 methods) were measured. LTB is a ratio of the lesion's PUVmax to the mean background; LTB1, LTB2, and LTB3 (which were calculated on different background) were used to designate the three values measured. Interobserver reliability between two readers for PUVmax and the LTBs was tested using the interobserver correlation coefficient (ICC). The likelihood ratio test was used to evaluate the relationship between ICCs. Receiver operating characteristic (ROC) curves were calculated for all methods. Diagnostic accuracy in differentiating benign tissue from malignant tissue was compared between PUVmax and LTB1. RESULTS The ICC rate was 0.971 [95 % confidence interval (CI) 0.943-0.986] for PUVmax, 0.873 (95 % CI 0.758-0.935) for LTB1, 0.965 (95 % CI 0.925-0.983) for LTB2, and 0.895 (95 % CI 0.799-0.946) for LTB3. However, there were some technical difficulties in the practical use of LTB2 and LTB3. The likelihood ratio test between PUVmax and LTB1 was statistically significant (p < 0.001). ROC curves of the 4 methods had similar characteristics. The median PUVmax was 1.39 for benign lesions and 3.70 for malignant lesions. LTB1 was 1.92 for benign lesions and 4.78 for malignant lesions. Significant differences (p < 0.001) in both PUVmax and LTB1 were observed between groups. CONCLUSION Due to its simplicity and reproducibility, PUVmax is superior to LTB as an indicator for PEM in semiquantitative analysis.
منابع مشابه
Diagnostic Accuracy of Positron Emission Mammography with 18F-fluorodeoxyglucose in Breast Cancer Tumor of Less than 20 mm in Size
Objective(s): To investigate the diagnostic accuracy of positron emission mammography (PEM) and positron emission tomography/computed tomography (PET/CT) for small breast tumors of less than 20 mm in size.Methods: The study was conducted on a total of 100 subjects (i.e., 50 patients with pathologically proven breast cancer and 50 normal cases of medical screening). The total number of tumors wa...
متن کاملClinical utility of positron emission mammography.
Several imaging modalities have been introduced over recent years to better screen for and stage breast cancer. Positron emission mammography (PEM) has been approved by the US Food and Drug Administration and introduced into clinical use as a diagnostic adjunct to mammography and breast ultrasonography. PEM has higher resolution and a more localized field of view than positron emission tomograp...
متن کامل“medical purposes to image and measure the distribution of injected positron emitting radiopharmaceuticals in human beings for the purpose of determining various metabolic and physiologic functions within the human body.” In March 2009, the Naviscan PEM Flex Solo II
Positron emission mammography (PEM) is a form of positron emission tomography (PET) that uses a high-resolution, mini-camera detection technology for imaging the breast. As with PET, PEM provides functional rather than anatomic information on the breast. This policy will address the use of PEM for presurgical planning and staging, monitoring response to therapy, and monitoring for recurrence of...
متن کاملComparison of Diagnostic Performance of Three-Dimensional Positron Emission Mammography versus Whole Body Positron Emission Tomography in Breast Cancer
Objective To compare the diagnostic performance of three-dimensional (3D) positron emission mammography (PEM) versus whole body positron emission tomography (WBPET) for breast cancer. Methods A total of 410 women with normal breast or benign or highly suspicious malignant tumors were randomized at 1 : 1 ratio to undergo 3D-PEM followed by WBPET or WBPET followed by 3D-PEM. Lumpectomy or maste...
متن کاملSoftware Tools for Breast Cancer Detection in Positron Emission Mammography Images
Positron Emission Mammography (PEM) is a novel imaging technology utilizing a dedicated Positron Emission Breast scanner. Two detectors in a configuration that resembles a conventional mammography (MG) machine cover a 250x120x200 mm3 volume, yielding 3D images of the breast, which is fixated between the detectors, but not compressed. The procedure depends on the administration of a radioactive ...
متن کامل