Comparison of Impact Strength and Fracture Morphology of Different Heat Cure Denture Acrylic Resins: An In vitro Study

نویسندگان

  • B Praveen
  • Harsha V Babaji
  • B G Prasanna
  • Santosh Kumar Rajalbandi
  • T V Shreeharsha
  • G M Prashant
چکیده

BACKGROUND The fracture of acrylic resin denture is rather common occurrence and causes inconvenience to the patients. This study was carried out to evaluate and compare the impact strength and fracture morphology of four different heat cure acrylic materials. MATERIALS AND METHODS Acrylic resin specimens were prepared using preformed metal die of dimension 65 × 10 × 3 mm. The specimens were finished, polished and subjected to impact strength evaluation using impact testing machine. The loads at which the specimens fracture are recorded and subjected to statistical analysis. Fracture surface analysis was done. Macroscopic analysis was performed by visual inspection of the fractured surfaces using a stereoscopic microscope. About 5 mm sections of all the fragments were subjected to scanning electron microscopy for microscopic analysis to verify fracture morphology. RESULTS Mean values of the impact strength were compared by statistical methods. The impact strength data were subjected to variance homogeneity tests. Fracture surface analysis data was analyzed by statistical methods. The mean impact strength of Lucitone 199 was higher than Acrylyn-H, DPI Heat cure & Trevalon. CONCLUSION Within the limitations of this study, it was concluded that the impact strength of the acrylic resins is affected by the reinforcement of fibers. Increased intermediate fractures increased impact strength. Brittle fractures morphology showed fewer undercuts and clearer surface. Intermediate fractures morphology showed more undercuts than clear surfaces.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Palatal Vault Depth Influence on the Flexural Strength of Two Heat Cure Acrylic Denture Base Resins - An In vitro Comparative Study

The aim of the study was to determine the effect of the flexural strength on denture bases fabricated on different palatal vault depths. Also, to compare the flexural strength of high impact heat cure resin with regular heat cure resin denture bases. Edentulous casts with deep, medium and shallow palatal vault depth were selected. Three different moulds were made in silicone duplicating materia...

متن کامل

Palatal vault depth influence on the flexural strength of two heat cure acrylic denture base resins: an in vitro study.

UNLABELLED Complete dentures often fracture during normal masticatory function. The reason could be due to the shape of the palate, i.e. deep, medium or shallow palatal vault. This in vitro study was performed to determine the relationship of palatal vault depth and flexural strength of two different permanent denture base resins. Edentulous maxillary casts of patients were collected from the d...

متن کامل

Comparative Evaluation of the Flexural Strength of Heat Polymerized Acrylic Resin with the Addition of 8% and 13% Aluminum Oxide Powder: An In-vitro Study

Introduction: Acrylic resins have been used successfully as denture bases. However, acrylic resin denture base materials are brittle and have poor strength and thermal conductivity. Therefore, it is essential to improve the flexural strength of heat polymerized acrylic resin. The present study aimed to evaluate and compare the flexural strength of heated polymerized acrylic res...

متن کامل

In-vitro Evaluation of Transverse Strength of Repaired Heat Cured Denture Base Resins without Surface Treatment and with Chemical and Mechanical Surface Treatment

BACKGROUND Denture repair involves joining two parts of a fractured denture with a denture repair material. Hence, a substantial repairing system for denture base fracture should be there to elude frequent fracture. MATERIALS AND METHODS Surface treatment of conventional heat cure denture base resin with different surface treatments (chemical ethyl acetate, and mechanical roughening with bur)...

متن کامل

Effects of Addition of Aluminum Oxide on Flexural Strength and Hardness of Acrylic Resins

Purpose: Acrylic dentures frequently fracture during service due totheir poor strength characteristics. The aim of this study was to evaluate the effects of adding 5%, 10% and 15% aluminum oxide powder on the flexural strength, surface hardness of a conventional heat-polymerized acrylic resin. Materials and methods: One of the commonly used conventional heat cure denture base resin (DPI) and hi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2014