Comparison of the root canal debridement ability of two single file systems with a conventional multiple rotary system in long oval-shaped root canals: In vitro study

نویسندگان

  • Elham khoshbin
  • Abbas Shokri
  • Zakieh Donyavi
  • Shahriar Shahriari
  • Golsa Salehimehr
  • Maryam Farhadian
  • Zeinab Kavandi
چکیده

BACKGROUND This study sought to compare the root canal debridement ability of Neolix, Reciproc and ProTaper rotary systems in long oval-shaped root canals. MATERIAL AND METHODS Eighty five extracted single-rooted human teeth with long oval-shaped single root canals were selected and divided into three experimental groups(n=25) and one control group (n= 10). Root canals were filled with Vitapex radiopaque contrast medium and prepared with Neolix, Reciproc or ProTaper systems. The control group only received irrigation. Digital radiographs were obtained at baseline and postoperatively and subjected to digital subtraction. The percentage of reduction in contrast medium was quantified at 0-5 mm and 5-10 mm distances from the apex. The data were analyzed using one-way ANOVA and t-test. RESULTS The mean percentage of the contrast medium removed was not significantly different in the 0-5mm segment among the three groups (P=0.6). In the 5-10mm segment a significant difference was found in this regard among the ProTaper and Reciproc groups (P=0.02) and the highest mean percentage of contrast medium was removed by ProTaper. But, difference between ProTaper and Neolix as well as Neolix and Reciproc was not significant. In Neolix (P=0.024) and Reciproc (P=0.002) systems, the mean percentage of the contrast medium removed from the 0-5mm segment was significantly greater than that in 5-10mm segment; however, this difference was not significant in ProTaper group (P=0.069). CONCLUSIONS Neolix single-file system may be a suitable alternative to ProTaper multiple-file system in debridement of long oval shaped canals. Key words:Root Canal Preparation, Debridement, Root Canal Therapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Canal Transportation and Centering Ability of Wave One and SafeSider in Curved Root Canals Using Cone-Beam Computed Tomography

Background and Aim: Maintaining the original central canal path during cleaning and shaping of the root canal system plays an important role in the success of endodontic treatment. This study sought to compare canal transportation and centering ability of WaveOne and SafeSider rotary files using cone-beam computed tomography (CBCT). Materials and Methods: This in-vitro, experimental study was ...

متن کامل

Suboptimal debridement quality produced by the single-file F2 ProTaper technique in oval-shaped canals.

INTRODUCTION The aim of this study was to determine whether the debridement quality of the single-file F2 ProTaper instrumentation technique is comparable to a full conventional ProTaper sequence in both round and oval-shaped root canals. METHODS Fifty-four recently extracted vital lower incisors were instrumented with either a full range of ProTaper Universal instruments in rotary motion (gr...

متن کامل

The self-adjusting file optimizes debridement quality in oval-shaped root canals.

INTRODUCTION Oval-shaped canals represent a challenge for rotary nickel-titanium (NiTi) files because buccal and/or lingual recesses are commonly left uninstrumented. The aim of the present study was to evaluate the debridement quality of the Self-Adjusting File (SAF) system in oval canals and compare it with the debridement achieved by a commonly used NiTi rotary system. METHODS A careful sp...

متن کامل

بررسی کاهش باکتری داخل کانال با سه روش مکانیکی Instrumentation، K- Type دستی، Race و Profile چرخشی

Statement of Problem: Root canal cleaning and elimination of the source of infection are the most important basis and the main requirements for successful root treatment since the main cause of failure in root treatment is the permeation of bacteria or their products into the periapical tissues. Nowadays, the newly designed and prcsented instruments for canal instrumentation can improve root tr...

متن کامل

مقایسه آماده‌سازی کانال ریشه با استفاده از فایل‌های نیکل تیتانیومی دستی و روتاری Race

Introduction: Successful treatment of root depends on complete elimination of debris and bacteria’s from root canal system and appropriate shaping of canal in obturation canal preparation is the most difficult and time consuming stage during root canal treatment. This stage especially in curved and narrow canals always causes some problems for students, general dentist and specialist. Following...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2017