Automated segmentation of routine clinical cardiac magnetic resonance imaging for assessment of left ventricular diastolic dysfunction.
نویسندگان
چکیده
BACKGROUND Cardiac magnetic resonance (CMR) is established for assessment of left ventricular (LV) systolic function but has not been widely used to assess diastolic function. This study tested performance of a novel CMR segmentation algorithm (LV-METRIC) for automated assessment of diastolic function. METHODS AND RESULTS A total of 101 patients with normal LV systolic function underwent CMR and echocardiography (echo) within 7 days. LV-METRIC generated LV filling profiles via automated segmentation of contiguous short-axis images (204+/-39 images, 2:04+/-0:53 minutes). Diastolic function by CMR was assessed via early:atrial filling ratios, peak diastolic filling rate, time to peak filling rate, and a novel index-diastolic volume recovery (DVR), calculated as percent diastole required for recovery of 80% stroke volume. Using an echo standard, patients with versus without diastolic dysfunction had lower early:atrial filling ratios, longer time to peak filling rate, lower stroke volume-adjusted peak diastolic filling rate, and greater DVR (all P<0.05). Prevalence of abnormal CMR filling indices increased in relation to clinical symptoms classified by New York Heart Association functional class (P=0.04) or dyspnea (P=0.006). Among all parameters tested, DVR yielded optimal performance versus echo (area under the curve: 0.87+/-0.04, P<0.001). Using a 90% specificity cutoff, DVR yielded 74% sensitivity for diastolic dysfunction. In multivariate analysis, DVR (odds ratio, 1.82; 95% CI, 1.13 to 2.57; P=0.02) was independently associated with echo-evidenced diastolic dysfunction after controlling for age, hypertension, and LV mass (chi(2)=73.4, P<0.001). CONCLUSIONS Automated CMR segmentation can provide LV filling profiles that may offer insight into diastolic dysfunction. Patients with diastolic dysfunction have prolonged diastolic filling intervals, which are associated with echo-evidenced diastolic dysfunction independent of clinical and imaging variables.
منابع مشابه
The Correlation between Left and Right Ventricular Ejection Fractions in Patients with Ischemic Heart Disease, Documented by Cardiac Magnetic Resonance Imaging
Introduction: The correlation between right and left ventricular ejection fractions (RVEF and LVEF, respectively) has been studied in only a small number of patients with a marked decrease in RVEF and LVEF. The aim of the present study was to compare LVEF and RVEF in patients with ischemic heart disease. RVEF and LVEF were measured by Cardiovascular Magnetic Resonance (CMR) imaging. Materials a...
متن کاملAutomated frame-by-frame endocardial border detection from cardiac magnetic resonance images for quantitative assessment of left ventricular function: validation and clinical feasibility.
PURPOSE To develop a technique based on image noise distribution for automated endocardial border detection from cardiac magnetic resonance (CMR) images throughout the cardiac cycle, validate it, and test its clinical utility. MATERIALS AND METHODS Images obtained in 36 patients were analyzed using custom software to obtain left ventricular (LV) volume throughout the cardiac cycle, end-systol...
متن کاملAssessment of Organ Specific Iron Overload in Transfusion-dependent Thalassemia by Magnetic Resonance Imaging Techniques
The consequence of repeated blood transfusions in thalassemia is iron overload in different organs. Magnetic resonance imaging (MRI) is a reliable, non-invasive and accurate method for iron detection in various tissues, hence the introduction of MRI has revolutionized the management of these patients and improved the life expectancy of them. Cardiac MRI T2* has a profound effect not only on est...
متن کاملImpact of diastolic dysfunction severity on global left ventricular volumetric filling - assessment by automated segmentation of routine cine cardiovascular magnetic resonance
OBJECTIVES To examine relationships between severity of echocardiography (echo) -evidenced diastolic dysfunction (DD) and volumetric filling by automated processing of routine cine cardiovascular magnetic resonance (CMR). BACKGROUND Cine-CMR provides high-resolution assessment of left ventricular (LV) chamber volumes. Automated segmentation (LV-METRIC) yields LV filling curves by segmenting a...
متن کاملAssessment of diastolic function from velocity-encoded cardiac magnetic resonance data in patients with hypertrophic cardiomyopathy
Background Diastolic dysfunction evaluation may be relevant for early diagnosis of hypertrophic cardiomyopathy (HCM) and subsequent risk assessment. The aim of our study was to assess phase contrast cardiac magnetic resonance (PCCMR) diastolic parameters obtained with a semi-automated method in relation to left ventricular (LV) remodeling and late gadolinium enhancement (LGE) in patients with HCM.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation. Cardiovascular imaging
دوره 2 6 شماره
صفحات -
تاریخ انتشار 2009