Macular thickness measurements in healthy Norwegian volunteers: an optical coherence tomography study

نویسندگان

  • Alexandra Wexler
  • Trond Sand
  • Tor B Elsås
چکیده

BACKGROUND Ethnic, intersubject, interoperator and intermachine differences in measured macular thickness seem to exist. Our purpose was to collect normative macular thickness data in Norwegians and to evaluate the association between macular thickness and age, gender, parity, and contraception status. METHODS Retinal thickness was measured by Stratus Optical Coherence Tomography in healthy subjects. Mean macular thickness (MMT) was analyzed by repeated measures ANOVA with three dependent regional MMT-variables for interaction with age, gender, parity and oral contraception use. Exploratory correlation with age by the Pearson correlation test, both before and after stratification by gender was performed. Differences in MMT between older and younger subjects, between oral contraception users and non-users, as well as parous and nulliparous women were studied by post-hoc Student's t-tests. RESULTS Central MMT in Norwegians was similar to values earlier reported in whites. MMT in central areas of 1 and 2.25 mm in diameter were higher in males than in females. In younger subjects (< or =43 years) differences in MMT between genders were larger than in the mixed age group, whereas in older subjects (>43 years) the small differences did not reach the set significance level. No differences were found in minimal foveolar thickness (MMFT) between the genders in any age group.Mean foveal thickness (1 mm in diameter) was positively associated with age in females (r = 0.28, p = 0.03). MMFT was positively associated with age in all groups and reached significance both in females and in mixed gender group (r = 0.20, p = 0.041 and r = 0.26, p = 0.044 respectively).Mean foveal thickness and MMFT were significantly higher in parous than in nulliparous women, and age-adjusted ANOVA for MMFT revealed a borderline effect of parity. CONCLUSIONS Age and gender should be taken into consideration when establishing normal ranges for MMT in younger subjects. The gender difference in retinal thickness in young, but not older adults suggests a gonadal hormonal influence. The possible association between parity and retinal structure and its clinical relevance, should be studied further.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Retinal Ganglion Cell Complex in Alzheimer Disease: Comparing Ganglion Cell Complex and Central Macular Thickness in Alzheimer Disease and Healthy Subjects Using Spectral Domain-Optical Coherence Tomography

Introduction: Alzheimer disease (AD) is the most common form of dementia worldwide. The modalities to diagnose AD are generally expensive and limited. Both the central nervous system (CNS) and the retina are derived from the cranial neural crest; therefore, changes in retinal layers may reflect changes in the CNS tissue. Optical coherence tomography (OCT) machine can show delicate retinal layer...

متن کامل

Clinical Applications of Optical Coherence Tomography in Ophthalmology

Assessment of the peripapillary nerve fiber layer and macular thickness can be determined in ophthalmology using optical coherence tomography (OCT). Decreased nerve fiber layer thickness and macular ganglion cell thickness in optic nerve ischemia have been correlated with visual field loss. OCT allows deep optic nerve head evaluation which helps understand pathophysiology of diseases.  Furtherm...

متن کامل

Correlation between Visual Acuity and Optical Coherence Tomography-Measured Retinal Thickness in Diabetic Macular Edema

Background and Objective: Diabetic macular edema (DME) is one of the common complications of diabetes which significantly accounts for preventable visual impairment and blindness. Central macular thickness (CMT) is a feature found in DME patients. This study aims to determine the relationship between optical coherence tomography (OCT)-measured CMT and visual acuity (VA) in patients with DME bef...

متن کامل

بررسی پایایی و تکرار پذیری دستگاه Spectral domain optical coherence tomography در اندازه گیری ضخامت ماکولا در چشمهای طبیعی قبل و بعد از گشاد کردن مردمک

Background: optical coherence tomography is one of the most valuable imaging techniques in the evaluation of macula. Objective: to investigate the repeatability and reproducibility of OCT  in measuring the macular thickness in normal eyes before and after pupil dilation. Methods: A total of 44 eyes were enrolled. All subjects underwent macular thickness measurement using the Cirrus SD-OCT ma...

متن کامل

Macular thickness measurements in healthy eyes using spectral optical coherence tomography.

AIM The aim of the present study was to measure macular thickness in healthy eyes and find whether it changes with age. MATERIAL AND METHODS We examined 163 healthy eyes of 84 healthy volunteers. In order to measure their macular thickness the patients were examined using spectral-domain optical coherent tomography (SD-OCT - iVue, Optovue). They were allocated into 6 age groups. RESULTS The...

متن کامل

Optical density filters modeling media opacities cause decreased SD-OCT retinal layer thickness measurements with inter- and intra-individual variation.

PURPOSE To assess the effect of media opacities on thickness measurements of the peripapillary retinal nerve fibre layer (pRNFL) and macular inner retinal layer (mIRL) performed with spectral-domain optical coherence tomography (SD-OCT) using a set of filters with known optical density. METHODS Spectral-domain optical coherence tomography volume scans of the optic disc and the macular area we...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2010