Effects of radiant exposure values using second and third generation light curing units on the degree of conversion of a lucirin-based resin composite

نویسندگان

  • Kelly Antonieta Oliveira Rodrigues de Faria CARDOSO
  • Driellen Christine ZARPELLON
  • Camila Ferreira Leite MADRUGA
  • José Augusto RODRIGUES
  • Cesar Augusto Galvão ARRAIS
چکیده

Objective Using Fourier transform infrared analysis (FTIR) in vitro, the effects of varying radiant exposure (RE) values generated by second and third generation LED LCUs on the degree of conversion (DC) and maximum rate of polymerization (Rpmax) of an experimental Lucirin TPO-based RC were evaluated. Material and Methods 1 mm or 2 mm thick silicon molds were positioned on a horizontal attenuated total reflectance (ATR) unit attached to an infrared spectroscope. The RC was inserted into the molds and exposed to varying REs (18, 36 and 56 J/cm2) using second (Radii Plus, SDI) and third generation LED LCUs (Bluephase G2/Ivoclar Vivadent) or a quartz tungsten based LCU (Optilux 501/SDS Kerr). FTIR spectra (n=7) were recorded for 10 min (1 spectrum/s, 16 scans/spectrum, resolution 4 cm-1) immediately after their application to the ATR. The DC was calculated using standard techniques for observing changes in aliphatic to aromatic peak ratios both prior to, and 10 min after curing, as well as during each 1 second interval. DC and Rpmax data were analyzed using 3-way ANOVA and Tukey's post-hoc test (p=0.05). Results No significant difference in DC or Rpmax was observed between the 1 mm or 2 mm thick specimens when RE values were delivered by Optilux 501 or when the 1 mm thick composites were exposed to light emitted by Bluephase G2, which in turn promoted a lower DC when 18 J/cm2 (13 s) were delivered to the 2 mm thick specimens. Radii Plus promoted DC and Rpmax values close to zero under most conditions, while the delivery of 56 J/cm2 (40 s) resulted in low DC values. Conclusions The third generation LCU provided an optimal polymerization of Lucirin TPO-based RC under most tested conditions, whereas the second generation LED-curing unit was useless regardless of the RE.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultra-fast light-curing resin composite with increased conversion and reduced monomer elution.

OBJECTIVES To test the null hypotheses that photoactive resin composites containing a Type I photoinitiator would exhibit reduced DC or increased monomer elution at substantially short curing times compared with materials based on a Type 2 ketone/amine system. METHODS Two experimental resin composites were prepared, using either Lucirin-TPO or camphorquinone/DMAEMA. Specimens were light-cured...

متن کامل

The Effect of Standard and Extended Curing Time in Different Distances on Composite’s Degree of Conversion

Introduction: The aim of this study was to in-vestigate the effect of irradiation duration and distance of light tip to prepared samples in two different light curing unites on the degree of conversion of resin composite. Materials and Methods: Conventional halogen and blue Light emitting diode (LED) units were used for polymerization of an Opalis resin com-posite. The conversion measurements w...

متن کامل

مقایسه آزمایشگاهی میزان پلیمریزاسیون کامپوزیت رزین P60 در زمان‌های نوردهی مختلف با دو دستگاه نوردهی

Background and Objective: Performance of resin composites depend on their polymerization rate. Minimum curing time to achieve desired polymerization rate is 40 seconds. P60 resin composite manufacturer has claimed reduced curing time as one of the advantages of this resin composite. Since increasing the lifetime of light curing unit and reducing the treatment period is important in pediatric...

متن کامل

Color Stability of a Microhybrid Resin Composite Polymerized with LED and QTH Light Curing Units

Introduction: Discoloration of resin composites is a common reason for replacement of these restorations. The aim of this study was to eva-luate the influence of different light curing de-vices on color stability of a microhybrid resin composite.  Materials and Methods: 80 disc-shaped speci-mens (8 mm in diameter, 2-mm height) were fabricated from filtek Z250 resin composite. Specimens wer...

متن کامل

The effects of Exposure Times and Light Curing Sources on Surface Micro-Hardness of a Resin Modified Glass Ionomer

Introduction: The aim of this study was to evaluate the influenceof different light curing systems and curing times on the micro-hardness of aresin modified glass ionomer. Methods: Forty two samples of ResinModified Glass Ionomer (RMGI) were prepared using stainless steel cylindrical mold(8 × 2 mm) and randomly divided into six groups of seven. Three groups werecured with a Quartz Tungsten Halo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 25  شماره 

صفحات  -

تاریخ انتشار 2017