Bio-Rad’s Bio-Plex® suspension array system, xMAP technology overview

نویسنده

  • Brett Houser
چکیده

The Bio-Plex(®) system utilizes xMAP technology to permit the multiplexing of up to 100 different analytes. Multiplex analysis gives researchers the ability to look at analytes simultaneously providing more information from less sample volume in less time than traditional immunoassay methods. Similar to ELISA, xMAP utilizes an antibody sandwich for detection but differs from ELISA in capture substrate and detection method. Rather than a flat surface, Bio-Plex(®) assays make use of differentially detectable bead sets as a substrate capturing analytes in solution and employs fluorescent methods for detection. These bead sets identify the analytes and detection antibodies are used to measure the quantity of analyte. The use of differentially detectable beads enables the simultaneous identification and quantification of many analytes in the same sample.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Multiplex Microsphere-Based Immunoassay Increases the Sensitivity of SIV-Specific Antibody Detection in Serum Samples and Mucosal Specimens Collected from Rhesus Macaques Infected with SIVmac239

Results from recent HIV-1 vaccine studies have indicated that high serum antibody (Ab) titers may not be necessary for Ab-mediated protection, and that Abs localized to mucosal sites might be critical for preventing infection. Enzyme-linked immunosorbent assay (ELISA) has been used for decades as the gold standard for Ab measurement, though recently, highly sensitive microsphere-based assays ha...

متن کامل

Comparison of multiplex immunoassay platforms.

BACKGROUND Candidate biomarkers discovered with high-throughput proteomic techniques (along with many biomarkers reported in the literature) must be rigorously validated. The simultaneous quantitative assessment of multiple potential biomarkers across large cohorts presents a major challenge to the field. Multiplex immunoassays represent a promising solution, with the potential to provide quant...

متن کامل

Use of Luminex xMAP bead-based suspension array for detecting microRNA in NSCLC tissues and its clinical application.

BACKGROUND We measured the expression of microRNA (miRNA) in non-small cell lung cancer (NSCLC) tissues using the Luminex xMAP bead-based suspension array. We discuss the feasibility of employing this method to detect miRNA in NSCLC and explore its value as a high-throughput miRNA array. METHODS We performed the methodological analysis of xMAP with oligoribonucleic acid references. We detecte...

متن کامل

A 7-plex microbead-based immunoassay for serotyping Shiga toxin-producing Escherichia coli.

Serotyping of Shiga toxin-producing Escherichia coli (STEC) has been contingent upon the availability of antisera. Here we describe a 7-plex microbead-based immunoassay to simultaneously serotype seven STECs (i.e., belonging to serogroups O26, O45, O103, O111, O121, O145, and O157) by the Luminex xMAP® technology. This technology presents many advantages: Its multiplexed format (up to 100 analy...

متن کامل

Quantum-dot-based suspension microarray for multiplex detection of lung cancer markers: preclinical validation and comparison with the Luminex xMAP® system

A novel suspension multiplex immunoassay for the simultaneous specific detection of lung cancer markers in bronchoalveolar lavage fluid (BALF) clinical samples based on fluorescent microspheres having different size and spectrally encoded with quantum dots (QDEM) was developed. The designed suspension immunoassay was validated for the quantitative detection of three lung cancer markers in BALF ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 118  شماره 

صفحات  -

تاریخ انتشار 2012