Development and evaluation of a contrast sensitivity perimetry test for patients with glaucoma.
نویسندگان
چکیده
PURPOSE To design a contrast sensitivity perimetry (CSP) protocol that decreases variability in glaucomatous defects while maintaining good sensitivity to glaucomatous loss. METHODS Twenty patients with glaucoma and 20 control subjects were tested with a CSP protocol implemented on a monitor-based testing station. In the protocol 26 locations were tested over the central visual field with Gabor patches with a peak spatial frequency of 0.4 cyc/deg and a two-dimensional spatial Gaussian envelope, with most of the energy concentrated within a 4 degrees circular region. Threshold was estimated by a staircase method: Patients and 10 age-similar control subjects were also tested on conventional automated perimetry (CAP), with the 24-2 pattern with the SITA Standard testing strategy. The neuroretinal rim area of the patients was measured with a retinal tomograph (Retina Tomograph II [HRT]; Heidelberg Engineering, Heidelberg, Germany). A Bland-Altman analysis of agreement was used to assess test-retest variability, compare depth of defect shown by the two perimetric tests, and investigate the relations between contrast sensitivity and neuroretinal rim area. RESULTS Variability showed less dependence on defect depth for CSP than for CAP (z = 9.3, P < 0.001). Defect depth was similar for CAP and CSP when averaged by quadrant (r = 0.26, P > 0.13). The relation between defect depth and rim area was more consistent with CSP than with CAP (z = 9, P < 0.001). CONCLUSIONS The implementation of CSP was successful in reducing test-retest variability in glaucomatous defects. CSP was in general agreement with CAP in terms of depth of defect and was in better agreement than CAP with HRT-determined rim area.
منابع مشابه
3135 Follow-up ocular hypertension with a modified test of the peripheral colour contrast sensitivity
Punme A definite need remains for accurate follow-up of limctional loss due to chronic open angle glaucoma, applicable in clinical practice. In 1991, the measurement of peripheral colour contrast sensitivity was introduced as a method for evaluating functional loss in incipient glaucoma (“ring test”)(Yu et al., IOVS, 32: 2779-2789). We modified this method in a way that thresholds arc now dctcn...
متن کاملComparison of Peristat Online Perimetry with the Humphrey Perimetry in a Clinic-Based Setting
PURPOSE We determined the receiver operating characteristic (ROC) curves for Peristat online perimetry at detecting varying degrees of glaucoma and the correlation between Peristat online perimetry and Humphrey visual field. METHODS A prospective, comparative study of Peristat online perimetry (an achromatic static computer threshold testing program) and Humphrey visual field (HVF) 24-2 SITA ...
متن کاملComparison of Standard Automated Perimetry, Short-Wavelength Automated Perimetry, and Frequency-Doubling Technology Perimetry to Monitor Glaucoma Progression
Detection of progression is paramount to the clinical management of glaucoma. Our goal is to compare the performance of standard automated perimetry (SAP), short-wavelength automated perimetry (SWAP), and frequency-doubling technology (FDT) perimetry in monitoring glaucoma progression.Longitudinal data of paired SAP, SWAP, and FDT from 113 eyes with primary open-angle glaucoma enrolled in the D...
متن کاملVariability components of standard automated perimetry and frequency-doubling technology perimetry.
PURPOSE To evaluate and compare intra- and intertest variability components for both standard automated perimetry (SAP) and frequency-doubling technology (FDT) perimetry in a small group of normal individuals and patients with glaucoma. METHODS The method of constant stimuli (MOCS) was used to examine matched test locations with both SAP and FDT perimetry stimuli in a group of eight normal in...
متن کاملA comparison of Goldmann and Humphrey automated perimetry in patients with glaucoma.
Humphrey automated threshold perimetry (Program 30-2) was performed on 42 eyes of 25 patients with glaucoma to determine both the sensitivity and specificity of automated perimetry in detecting glaucomatous visual field defects. Automated perimetry sensitivity was 90.38%, while automated perimetry specificity was 91%. Fifty-two patients and a technician took part in a survey to determine their ...