Invasive versus noninvasive evaluation of coronary artery disease.

نویسندگان

  • Joanne D Schuijf
  • Jacob M van Werkhoven
  • Gabija Pundziute
  • J Wouter Jukema
  • Isabel Decramer
  • Marcel P Stokkel
  • Petra Dibbets-Schneider
  • Martin J Schalij
  • Johannes H C Reiber
  • Ernst E van der Wall
  • William Wijns
  • Jeroen J Bax
چکیده

OBJECTIVES We sought to compare the diagnostic information obtained from noninvasive characterization of coronary artery disease by using multidetector computed tomography (MDCT) and myocardial perfusion imaging (MPI) and to compare findings with the use of invasive coronary angiography and intravascular ultrasound (IVUS). BACKGROUND Preliminary comparisons have suggested that abnormal myocardial perfusion studies correlate well with significant luminal stenosis on MDCT coronary angiography. However, atherosclerotic coronary lesions may be detectable with the use of MDCT even in the presence of normal myocardial perfusion METHODS We performed MDCT, MPI, and conventional coronary angiography in 70 patients. In addition, IVUS was performed in 53 patients. Quantitative information was obtained from quantitative coronary angiography (QCA) and IVUS assessment of plaque burden and minimal luminal area. RESULTS Of 26 patients with an abnormal MPI study, 23 (88%) showed significant stenosis on MDCT. As compared with QCA, MDCT showed a sensitivity of 96% and specificity of 67% for the detection of stenoses > or =50% diameter narrowing in these patients. Mean diameter stenosis on QCA was 76% and mean minimal lumen area in IVUS was 3.3 mm(2). On the other hand, 27 (84%) of 44 patients with normal MPI had evidence of coronary atherosclerosis on MDCT (luminal stenosis > or =50%: n = 15, luminal stenosis <50%: n = 12, sensitivity of 100% and specificity of 83% as compared with QCA). Using IVUS, we found substantial plaque burden (mean 58.9 +/- 18.1% of cross-sectional area), but presence of a stenosis (minimal lumen area <4.0 mm(2)) in only 14 patients (mean minimal lumen area, 5.8 +/- 3.3 mm(2)). Only 7 patients with normal myocardial perfusion scans demonstrated absence of coronary atherosclerosis by MDCT. CONCLUSIONS Considerable plaque burden can be observed with MDCT even in the absence of myocardial perfusion abnormalities. This finding does not constitute a false-positive MDCT result, but rather reflects the fact that MDCT can detect atherosclerotic lesions that are not flow-limiting.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Myocardial perfusion scan accuracy in detection of coronary artery disease - Comparison with exercise stress test [Persian]

Introduction: In patients with coronary artery disease (CAD) noninvasive evaluation for detection of ischemia is important to avoid invasive interventions like angiography. Exercise stress test is conventionally the first study used in evaluation of CAD. Considering the noninvasive nature of the myocardial perfusion scan, we decided to compare its accuracy with stress test. Methods: Patie...

متن کامل

Noninvasive evaluation of the coronary arteries with multislice computed tomography in hypertensive patients.

Because patients with hypertension are at increased risk for coronary artery disease, early and noninvasive identification of the disease in patients with hypertension is important. Recently, multislice computed tomography (MSCT) has been demonstrated to allow both noninvasive coronary angiography and assessment of left ventricular function. The purpose of the present study therefore was to dem...

متن کامل

بررسی تأثیر پارامترهای پیوسته در تشخیص بیماری عروق کرونر قلبی با استفاده از شبکه‌های عصبی مصنوعی

Background & Aim: Coronary artery disease is among the common diseases in societies. The best method of assessing coronary artery diseases is through angiography. This study aimed at investigating the effect of disease parameters on the diagnosis of coronary artery disease using artificial neural networks. Methods: This analytic study included a database of 200 non-attributable records. In t...

متن کامل

Noninvasive coronary vessel wall and plaque imaging with magnetic resonance imaging.

BACKGROUND Conventional x-ray angiography frequently underestimates the true burden of atherosclerosis. Although intravascular ultrasound allows for imaging of coronary plaque, this invasive technique is inappropriate for screening or serial examinations. We therefore sought to develop a noninvasive free-breathing MR technique for coronary vessel wall imaging. We hypothesized that such an appro...

متن کامل

New technology for noninvasive evaluation of coronary artery disease.

Cardiac computed tomography (CT) and positron emission tomography (PET) are emerging as powerful noninvasive imaging tools for the evaluation of atherosclerosis in patients with known or suspected coronary artery disease (CAD). Unlike invasive coronary angiography, CT coronary angiography (CTA) not only assesses disease within the coronary lumen but can also provide direct qualitative and quant...

متن کامل

New Technology for Noninvasive Evaluation of Coronary Artery Disease

Cardiac computed tomography (CT) and positron emission tomography (PET) are emerging as powerful noninvasive imaging tools for the evaluation of atherosclerosis in patients with known or suspected coronary artery disease (CAD). Unlike invasive coronary angiography, CT coronary angiography (CTA) not only assesses disease within the coronary lumen but can also provide direct qualitative and quant...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JACC. Cardiovascular imaging

دوره 1 2  شماره 

صفحات  -

تاریخ انتشار 2008