High-dose intensity-modulated radiotherapy as primary therapy for prostate cancer: report on dosimetry aspects and acute toxicity in the Indian scenario.

نویسندگان

  • Sandeep De
  • Venkatesan Kannan
  • Sudesh Deshpande
  • Vivek Anand
  • Yogesh Ghadi
چکیده

BACKGROUND AND PURPOSE Dose escalation improves local control in prostate cancer. In this study we assess the feasibility of dose escalation to prostate and / or seminal vesicles to 76 Gy with intensity-modulated radiotherapy (IMRT); report data on dosimetry and acute toxicity in 40 patients at P. D. Hinduja National Hospital and Medical Research Center, Mumbai. MATERIALS AND METHODS In the period from May 2006 to September 2008, 40 consecutive patients with localized prostate adenocarcinoma (T1- 3 N0) were definitively treated with IMRT to a dose of 76 Gy / 38 fractions. Patients were seen on a weekly basis during treatment, and one month (M1) and three months (M3) thereafter. The radiation therapy oncology group (RTOG) toxicity scale was used to evaluate acute gastrointestinal (GI) and genitourinary (GU) toxicities. Additional symptoms such as rectal blood loss, urgency, dysuria, urinary frequency, nocturia, incontinence were scored as well. RESULTS All 40 patients completed treatment successfully. Acute RTOG Grade 1 and Grade 2 GI toxicities were noted in 47.5% (19 patients) and 12.5% (five patients) respectively, leaving 40% (16 patients) free of any acute toxicity. Thirty-six (90%) and four patients (10%) had Grade 0-1 and Grade 2 acute RTOG-scaled GU toxicity respectively. There was no Grade 3 or higher GI / GU toxicity. CONCLUSIONS The escalated dose of 76 Gy to the prostate with IMRT was very well tolerated by all our patients with acceptable acute GU and GI toxicity, thereby, establishing the feasibility of dose escalation in the Indian scenario.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Early toxicity of moderate hypofractionated volumetric modulated Arc radiotherapy for localized prostate cancer

Background: Based on the radiation biology model of prostate cancer, hypofractionated radiotherapy can improve the treatment outcomes without increasing toxicity. Although hypofractionated radiotherapy is implemented over a short period of time, it is more convenient and cheaper compared with conventional fractionated treatment. The aim of this study was to investigate the early toxicity of mod...

متن کامل

Assessment and Comparison of Homogeneity and Conformity Indexes in Step-and-Shoot, Compensator-Based Intensity Modulated Radiation Therapy (IMRT) and Three-Dimensional Conformal Radiation Therapy (3D CRT) in Prostate Cancer

Introduction: Intensity modulated radiation therapy (IMRT) and three-dimensional conformal radiation therapy (3D CRT) are two treatment modalities in prostate cancer, which provide acceptable dose distribution in tumor region with sparing the surrounding normal tissues. IMRT is based on inverse planning optimization; in which, intensity of beams is modified by using multileaf c...

متن کامل

Out-of-field photon dosimetry study between 3-D conformal and intensity modulated radiation therapy in the management of prostate cancer

Background: The present work aims to study the out-of-field photon calculation accuracy of a commercial treatment planning system (TPS), Oncentra, for three-dimensional conformal radiotherapy (3D-CRT) and intensity modulated radiation therapy (IMRT) treatment techniques from Elekta Synergy medical linear accelerator. Materials and Methods: Accuracy of individual out-of-field dose components was...

متن کامل

Dosimetry evaluation of salivary glands in 3D conformal radiotherapy and intensity modulated radiotherapy in oral tongue cancer

Introduction: The purpose of this study was to evaluate the dosimetric and radiobiological parameters of salivary glands in treatment of patients with oral tongue cancer by 3D conventional radiotherapy (3D-CRT) and intensity modulated radiation therapy (IMRT) techniques. Materials and Methods: This study was performed on treatment planning of patients with oral tongue cancer in T2-3/N0 cancer s...

متن کامل

Dose Distribution Analysis of Rapid Arc and Intensity Modulated Radiotherapy Plan in Head and Neck Cancer

Introduction: Globally, intensity-modulated radiation therapy (IMRT) is considered as highly precise and accurate method of radiotherapy planning. This technique amplifies spatial dose distribution conformity by modulating the intensity of radiation beams in each sub-volume. Additionally, it can reduces the dose to surrounding critical organs and deliver the planned dose to targets with the nom...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cancer research and therapeutics

دوره 6 1  شماره 

صفحات  -

تاریخ انتشار 2010