Effective Height of a Floor Splitter Anti-Vortex Device under Varying Flow Conditions
نویسندگان
چکیده
A pump station is a very important flood control facility for mitigating inundation of urban lowland areas. It is not easy to secure a site to increase the capacity of a pump station in an urban area because of various limitations or to maximize the discharge capacity of the pump sump. Adding a facility to improve the pump capacity of a pump station may affect the flow characteristics, such as unexpected increases in the flow velocity and vorticity, and cause severe problems with operating the pump station. To solve those problems, anti-vortex devices (AVDs) have been developed and adopted for appropriate design standards. The Korean design criteria for AVDs are based on experience and foreign standards because not enough data on the AVD are available. In this study, the flow in the sump was numerically simulated at various AVD heights to collect information on improving the design and efficiency of a pump station. Consequently, an appropriate height for the AVD and changes in the flow pattern and vortex in the pump sump were determined and compared with 12 cases of inflow conditions with respect to the vertical location.
منابع مشابه
Experimental Investigation of the Effect of Splitter Plate Angle on the Under-Scouring of Submarine Pipeline Due to Steady Current and Clear Water Condition
Submarine pipelines are appropriate method for transmission of oil and gas from sea bed. Free spans may occur due to the natural uneven seabed or by under-scouring. Vortex Induced Vibration (VIV) can happen in such free spans at high Reynolds number. Resonance occurs if the frequency of vortex shedding is close to the pipeline’s natural frequency leading to its fatigue that can break the pipeli...
متن کاملمطالعه آزمایشگاهی تأثیر تعداد و زاویه گردابشکن بر مشخصات جریان در سرریز نیلوفری مربعی
Morning glory spillway is one of the spillways and used when it is not possible to use any other spillways. With the onset of submergence and flow loss, and intensification of circulation and vortexes, spillway performance decreases severely. With decreasing discharge coefficient, the height of water in the reservoir increases and the risk of dam damage, caused by the lack of spillway ability o...
متن کاملTwin Plate Weir: A Flow Measuring Device (TECHNICAL NOTE)
For efficient use of water, accurate measurement of flow in (field/laboratory) channels is required for many water resource projects. The present work is aimed to study the flow characteristics of a twin plate weir (two sharp-crested plates are placed one behind the other at some distance) under free and submerged flow conditions. Experiments are performed with four spacing of the twin plate we...
متن کاملSuppression of vortex-induced forces on a two-dimensional circular cylinder by a short and thin splitter plate interference
This paper briefly reviews bluff body aerodynamics and focuses mainly on the use of short and thin splitter plates to interfere with the vortex wakes and suppress vortex-induced forces (VIF). The present investigation primarily examines the suppression of unsteady, two-dimensional wake instabilities over a low Reynolds number range of less than 250. A circular cylinder is used as the bluff body...
متن کاملNumerical Study on Hydrodynamics and Heat Transfer Characteristics Around a Cylinder with Inclined Splitter Plates
In the current paper, the effect of length and angle of a splitter plate on hydro-thermal field in a range of Reynolds number from 40 to 1000 are numerically studied by solving the two-dimensional Navier-Stokes equations. For discretization of governing equations, PISO algorithm was imposed to segregate the pressure-velocity coupled equations, and second-order upwind discretization scheme was a...