Pulse oximetry monitoring during non-sedated upper gastrointestinal endoscopy.
نویسندگان
چکیده
Fifty consecutive patients judged fit for non-sedated upper gastrointestinal endoscopy were monitored by pulse oximetry before, during and after the procedure. Transient hypoxia developed during intubation in five subjects (10%) but treatment was not required nor was the test halted. Only one patient with pre-existing respiratory problems became hypoxaemic to the extent that oxygen had to be given and the procedure halted. The chance of hypoxia was unrelated to age, sex, smoking, anxiety, or the duration of intubation. Routine pulse oximetry is not necessary for non-sedated gastroscopy but oximetry monitoring may be important in selected cases.
منابع مشابه
The role of sedation and pulse oximetry during upper gastrointestinal endoscopy.
INTRODUCTION To determine the changes in oxygen saturation, blood pressure and pulse rate during endoscopic procedure and to evaluate--oesophagogastroduodenoscopy (OGD) related discomfort assessed by the patient. METHODS It is observational case control study. Baseline pulse, blood pressure and oxygen saturation were monitored before procedure, at one minute of procedure, at five minute and s...
متن کاملPulse oximetry and cardiorespiratory changes during upper gastrointestinal endoscopy in dogs
Objective- The objective of the present study was to determine the changes in heart rate, respiratory rate and arterial Oxygen saturation (SpO2) by administration of three drug combinations during upper gastrointestinal endoscopy. Design- Experimental study. Animals- 21 healthy and adults dog were randomly divided into three groups. Procedures- The IV combination of 6.5 mg/kg ketamine and 0....
متن کاملفاکتورهای پیش بینی کننده کاهش اشباع اکسیژن خون شریانی در طی آندوسکوپی فوقانی در بیماران بدون دریافت داروی آرامبخش
Introduction: Hypoxemia can occur during upper gastrointestinal endoscopy with or without pharmacological sedation. Pulse oximetry saturation (SpO2) levels were assessed in patients attending for routine unsedated diagnostic upper gastrointestinal endoscopy to identify factors associated with oxygen desaturation. Methods: A total of 300 patients who underwent upper gastrointestinal endoscopy w...
متن کاملHypoxia during upper gastrointestinal endoscopy with and without sedation and the effect of pre-oxygenation on oxygen saturation.
In Study A, the incidence of arterial oxygen desaturation was studied using pulse oximetry (SaO2) in 100 sedated and 100 nonsedated patients breathing room air who underwent diagnostic upper gastrointestinal endoscopy. Hypoxia (SaO2 92% or less of at least 15 s duration) occurred in 17% and 6% of sedated patients and nonsedated patients, respectively (p < 0.03). Mild desaturation (SaO2 94% or l...
متن کاملCapnography is superior to pulse oximetry for the detection of respiratory depression during colonoscopy.
BACKGROUND Pulse oximetry is a widely accepted procedure for ventilatory monitoring during gastrointestinal endoscopy, but this method provides an indirect measurement of the respiratory function. In addition, detection of abnormal ventilatory activity can be delayed, especially if supplemental oxygen is provided. Capnography offers continuous real-time measurement of expiratory carbon dioxide....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Postgraduate medical journal
دوره 71 837 شماره
صفحات -
تاریخ انتشار 1995