Variation in the human Achilles tendon moment arm during walking.
نویسندگان
چکیده
The Achilles tendon (AT) moment arm is an important determinant of ankle moment and power generation during locomotion. Load and depth-dependent variations in the AT moment arm are generally not considered, but may be relevant given the complex triceps surae architecture. We coupled motion analysis and ultrasound imaging to characterize AT moment arms during walking in 10 subjects. Muscle loading during push-off amplified the AT moment arm by 10% relative to heel strike. AT moment arms also varied by 14% over the tendon thickness. In walking, AT moment arms are not strictly dependent on kinematics, but exhibit important load and spatial dependencies.
منابع مشابه
Achilles tendon moment arm in humans is not affected by inversion/eversion of the foot: a short report
The triceps surae primarily acts as plantarflexor of the ankle joint. However, the group also causes inversion and eversion at the subtalar joint. Despite this, the Achilles tendon moment arm is generally measured without considering the potential influence of inversion/eversion of the foot during plantarflexion. This study investigated the effect of foot inversion and eversion on the plantarfl...
متن کاملRunning biomechanics: shorter heels, better economy.
Better running economy (i.e. a lower rate of energy consumption at a given speed) is correlated with superior distance running performance. There is substantial variation in running economy, even among elite runners. This variation might be due to variation in the storage and reutilization of elastic energy in tendons. Using a simple musculoskeletal model, it was predicted that the amount of en...
متن کاملChanges in Achilles tendon moment arm from rest to maximum isometric plantarflexion: in vivo observations in man.
1. The purpose of the present study was to examine the effect of a plantarflexor maximum voluntary contraction (MVC) on Achilles tendon moment arm length. 2. Sagittal magnetic resonance (MR) images of the right ankle were taken in six subjects both at rest and during a plantarflexor MVC in the supine position at a knee angle of 90 deg and at ankle angles of -30 deg (dorsiflexed direction), -15 ...
متن کاملInteractive effects of joint angle, contraction state and method on estimates of achilles tendon moment arms.
The muscle-tendon moment arm is an important input parameter for musculoskeletal models. Moment arms change as a function of joint angle and contraction state and depend on the method being employed. The overall purpose was to gain insights into the interactive effects of joint angle, contraction state and method on the Achilles tendon moment arm using the center of rotation (COR) and the tendo...
متن کاملChanges of the Patellar Tendon Moment arm Length in Different Knee Angles: A Biomechanical in Vivo Study
Patellar tendon moment arm length (PTma) changes at different knee flexion angles have not been determined in invivo studies. We aimed to determine PTma in four different knee angles using Magnetic Resonance Imaging (MRI) topredict in vivo changes in the moment arm length from different knee angles during running.PTma was measured as the perpendicular distance from muscle–tend...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Computer methods in biomechanics and biomedical engineering
دوره 20 2 شماره
صفحات -
تاریخ انتشار 2017