Importance of sleep stage- and body position-dependence of sleep apnoea in determining benefits to auto-CPAP therapy.
نویسندگان
چکیده
The influence of sleep stage- and body position-dependence of sleep apnoea on treatment efficacy and compliance between conventional continuous positive airway pressure (CPAP) and auto CPAP therapy was evaluated. Thirty-three newly treated sleep apnoea hypopnoea syndrome (SAHS) patients were randomly allocated to conventional or auto-CPAP therapy. Six patients of each treatment group were classified as having sleep stage- and body position-dependent obstructive breathing abnormalities according to the results of the baseline sleep study. After 3 weeks of treatment, the Epworth sleepiness score tended to be higher (p = 0.08) and the ability to stay awake lower (p = 0.02) in patients with dependent breathing abnormalities treated with fixed CPAP, than in the other patients. The effective pressure/time index was significantly lower in sleep stage- and body position-dependent patients treated with fixed CPAP, than in the other patients (p = 0.02). The number of hours the machine was turned on and a positive pressure applied, tended to be smaller in dependent patients treated with fixed CPAP than in independent patients of this treatment group and in patients treated with auto-CPAP. A night-to-night variability index (VI) of positive pressure changes was obtained in the auto-CPAP group. This index significantly decreased with time in the dependent patients while it remained unchanged in the independent group. It is concluded that auto-continuous positive airway pressure may have specific indications in a subset of obstructive sleep apnoea patients with sleep stage- and body position dependent nocturnal breathing abnormalities.
منابع مشابه
An auto-continuous positive airway pressure device controlled exclusively by the forced oscillation technique.
The forced oscillation technique (FOT) has been demonstrated to be a very sensitive tool for the assessment of upper airway obstruction during nasal continuous positive airway pressure (CPAP) therapy for obstructive sleep apnoea (OSA). The present study was designed to evaluate the therapeutic efficacy of a novel auto-CPAP device based exclusively on the FOT. Following manual CPAP titration, 18...
متن کاملComparison of three auto-adjusting positive pressure devices in patients with sleep apnoea.
Auto-adjustable continuous positive airway pressure (APAP) devices are an emerging treatment alternative to fixed-pressure continuous positive airway pressure (CPAP) therapy for obstructive sleep apnoea syndrome. They have been engineered to automatically adjust the pressure to the optimal level on a continuous basis. However, not all APAP technologies use the same algorithm. Three different AP...
متن کاملEffect of chronic continuous positive airway pressure (CPAP) therapy on upper airway size in patients with sleep apnoea/hypopnoea syndrome.
BACKGROUND There is evidence to suggest that chronic continuous positive airway pressure (CPAP) therapy may produce reversible changes in upper airway morphology and function in patients with sleep apnoea/hypopnoea. This study was designed to examine the effect of chronic CPAP therapy on upper airway calibre. METHODS Twenty four men with the sleep apnoea/hypopnoea syndrome (mean (SE) apnoea/h...
متن کاملTwo months follow up of auto-CPAP treatment in patients with obstructive sleep apnoea.
BACKGROUND Continuous positive airway pressure (CPAP) with fixed mask pressure is the current standard treatment for obstructive sleep apnoea (OSA). Auto-CPAP devices apply at any time the minimally required pressure to normalise breathing and may improve patient comfort and compliance. We present an open descriptive study of auto-CPAP treatment at home in patients previously managed with conve...
متن کاملEvaluation of an auto-CPAP device for treatment of obstructive sleep apnoea.
BACKGROUND Auto-CPAP machines used in the treatment of obstructive sleep apnoea (OSA) are designed to vary the treatment pressure automatically in order always to apply the actually needed pressure. Consequently they should be able to achieve at least identical therapeutic effects as conventional constant pressure CPAP with a lower mean treatment pressure. The present study was designed to eval...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The European respiratory journal
دوره 18 1 شماره
صفحات -
تاریخ انتشار 2001