Left ventricle: automated segmentation by using myocardial effusion threshold reduction and intravoxel computation at MR imaging.
نویسندگان
چکیده
UNLABELLED This retrospective analysis of existing patient data had institutional review board approval and was performed in compliance with HIPAA. No informed consent was required. The purpose of the study was to develop and validate an algorithm for automated segmentation of the left ventricular (LV) cavity that accounts for papillary and/or trabecular muscles and partial voxels in cine magnetic resonance (MR) images, an algorithm called LV Myocardial Effusion Threshold Reduction with Intravoxel Computation (LV-METRIC). The algorithm was validated in biologic phantoms, and its results were compared with those of manual tracing, as well as those of a commercial automated segmentation software (MASS [MR Analytical Software System]), in 38 subjects. LV-METRIC accuracy in vitro was 98.7%. Among the 38 subjects studied, LV-METRIC and MASS ejection fraction estimations were highly correlated with manual tracing (R(2) = 0.97 and R(2) = 0.95, respectively). Ventricular volume estimations were smaller with LV-METRIC and larger with MASS than those calculated by using manual tracing, though all results were well correlated (R(2) = 0.99). LV-METRIC volume measurements without partial voxel interpolation were statistically equivalent to manual tracing results (P > .05). LV-METRIC had reduced intraobserver and interobserver variability compared with other methods. MASS required additional manual intervention in 58% of cases, whereas LV-METRIC required no additional corrections. LV-METRIC reliably and reproducibly measured LV volumes. SUPPLEMENTAL MATERIAL http://radiology.rsnajnls.org/cgi/content/full/248/3/1004/DC1.
منابع مشابه
A Semi-Automated Algorithm for Segmentation of the Left Atrial Appendage Landing Zone: Application in Left Atrial Appendage Occlusion Procedures
Background: Mechanical occlusion of the Left atrial appendage (LAA) using a purpose-built device has emerged as an effective prophylactic treatment in patients with atrial fibrillation at risk of stroke and a contraindication for anticoagulation. A crucial step in procedural planning is the choice of the device size. This is currently based on the manual analysis of the “Device Landing Zone” fr...
متن کاملAn Automated 4D Approach for Left Ventricular Assessment in Clinical Cine MR Images
Cine Magnetic Resonance (MR) imaging has become the method-of-choice for the examination of the dynamic behaviour of the heart. An assessment of the left ventricle can reveal regions of myocardial dysfunction and their severeness. The scope of this work is a complete analysis of the left ventricular dynamics for the usage in a clinical environment. For that purpose, endocardial and epicardial b...
متن کاملPerformance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT
Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...
متن کاملAutomated Segmentation of Left Ventricle in Cine Cardiac MR Images: Experience From a Large Study
Introduction: To quantitatively analyze global and regional cardiac function from MR, clinical parameters such as ejection fraction (EF) and left ventricular mass are required. These depend upon accurate delineation of endocardial and epicardial contours of the left ventricle (LV). Accurate LV segmentation is acknowledged as a difficult problem because of: 1) the lack of edge information; 2) th...
متن کاملAtlas-Based Segmentation and Tracking of 3D Cardiac MR Images Using Non-rigid Registration
We propose a novel method for fully automated segmentation and tracking of the myocardium and left and right ventricles (LV and RV) using 4D MR images. The method uses non-rigid registration to elastically deform a cardiac atlas built automatically from 14 normal subjects. The registration yields robust performance and is particularly suitable for processing a sequence of 3D images in a cardiac...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiology
دوره 248 3 شماره
صفحات -
تاریخ انتشار 2008