Automation of bone marrow aspirate examination using the XE-2100 automated hematology analyzer.

نویسندگان

  • Yusuke Mori
  • Toshihiro Mizukami
  • Yukio Hamaguchi
  • Kazuto Tsuruda
  • Yasuaki Yamada
  • Shimeru Kamihira
چکیده

BACKGROUND Attempts to analyze bone marrow aspirates have been reported with the use of several automated blood cell counters, but sufficient accuracy in examination is not acquired yet. Major problems have included difficulties in correctly differentiating various immature cells and interference by lipid in bone marrow aspirates. The goal of this study was to solve these problems to attain more accurate assessment of bone marrow aspirates with automated blood cell counters. METHODS We modified the XE-2100 Automated Hematology Analyzer (Sysmex Corporation, Kobe, Japan) to fit it for bone marrow aspirate measurement and evaluated its performance. Measurements were performed with the modified XE-2100 on 81 patient samples of bone marrow aspirates; as a reference, the manual visual method was used and flow cytometric analysis were carried out. RESULTS Good correlations between results with the modified XE-2100 and the manual visual method were obtained for total nucleated cell count (TNCC; r = 0.99), erythroblast/TNCC ratio (r = 0.93), and myeloid cell/TNCC ratio (r = 0.75). CONCLUSIONS When this device is used, bone marrow aspirate differentials can be determined quickly and easily. This device will be useful for preliminary examination to obtain a summary of various blood cell ratios in bone marrow aspirates before performance of microscopic examination.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preliminary Data on the Feasibility of Bone Marrow Screening on the Sysmex XE-2100 Automated Hematology Analyzer

In the present study we investigated the potential of the Sysmex XE-2100 automated hematology analyzer as a screening device for bone marrow (BM) aspirates. We evaluated BM cellularity, white blood cell (WBC) differential count, immature granulocyte (IG) count, nucleated red blood cell (NRBC) count, granulocyte/erythroid (G/E) and myeloid/erythroid (M/E) ratio, and potential pathologyrelated sc...

متن کامل

Evaluation of the Diagnostic Performance of theSysmex XT-2000i Automated Hematology Analyzerin the Detection of Immature Granulocyte

Immature Granulocytes (IG) are normally not present in peripheral blood. Their presence is an important indicator of enhanced bone marrow activation. The present study evaluated the diagnostic performance of the Sysmex XT-2000i automated hematology analyzer in the detection of myelocytes and/or metamyelocytes in patients affected by non-haematological disease, in comparison with manual microsco...

متن کامل

Performance evaluation of the immature granulocyte parameter on the Sysmex XE-2100 automated hematology analyzer.

Recently, St. Anthony's Medical Center Laboratory (SAMC) in St. Louis, Missouri, installed a new automated hematology analyzer, the Sysmex XE-2100. The XE-2100 has an additional differential parameter, the immature granulocyte (IG) parameter. Prior to implementation, the IG parameter was evaluated by comparison to the manual immature granulocyte count. Immature granulocytes counted manually, as...

متن کامل

Automatic analysis of normal bone marrow blood cells using the XE-2100 automated hematology analyzer.

The bone marrow aspiration test conventionally has been performed by visual methods, using a light microscope, because automatic blood cell analyzers cannot adequately capture erythroblasts and immature granulocytes (IGs) (Tatsumi et al.: Osaka City Med J 1988;34:135-146; Tatsumi et al.: Am J Clin Pathol 1986;86:50-54). With the development of the XE-2100 automatic blood cell analyzer (Sysmex C...

متن کامل

First basic performance evaluation of the XE-2100 haematology analyser

The newly developed XE-2100 haematology analyser can provide complete blood counts, leukocyte differentials, perform reticulocyte analysis, and obtain quantitative data on nucleated red blood cells (NRBCs). In this study, we evaluated the basic performance of this instrument using routinely obtained blood specimens treated with ethylenediaminetetraacetic acid-2K. Reproducibility, carryover, sta...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cytometry. Part B, Clinical cytometry

دوره 58 1  شماره 

صفحات  -

تاریخ انتشار 2004