Integration of monolithic frit into the particulate capillary (IMFPC) column in shotgun proteome analysis.

نویسندگان

  • Fangjun Wang
  • Jing Dong
  • Mingliang Ye
  • Ren'an Wu
  • Hanfa Zou
چکیده

Capillary column plays an important role in nano-flow liquid chromatography coupled with tandem mass spectrometry for dealing with the high dynamic range and complexity of protein samples in shotgun proteome analysis. In this study, the integrated monolithic frit into the particulate capillary (IMFPC) column was prepared. By comparing the prepared IMFPC column with conventionally fritless capillary column, smaller size of packing materials could be easily packed into the capillary to achieve higher average peak capacity and proteome coverage. As the monolithic emitter was integrated onto this type of column, the void volume between packing particles and electrospray emitter was eliminated and the electrospray quality was improved. The prepared IMFPC column was applied to proteome analysis of mouse liver extracts, and it was observed that the number of identified proteins and peptides increased 14.9 and 12.9% as well as the peak capacity increased 11.6% by using IMFPC column over conventionally fritless capillary column.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dual-purpose sample trap for on-line strong cation-exchange chromatography/reversed-phase liquid chromatography/tandem mass spectrometry for shotgun proteomics. Application to the human Jurkat T-cell proteome.

A dual-purpose sample-trapping column is introduced for the capacity enhancement of proteome analysis in on-line two-dimensional nanoflow liquid chromatography (strong cation-exchange chromatography followed by reversed-phase liquid chromatography) and tandem mass spectrometry. A home-made dual trap is prepared by sequentially packing C18 reversed-phase (RP) particles and SCX resin in a silica ...

متن کامل

Octadecylated silica monolith capillary column with integrated nanoelectrospray ionization emitter for highly efficient proteome analysis.

An improved strategy for the preparation of octadecylated silica monolith capillary column with high homogeneity was proposed. Column performance was evaluated by nanoscale HPLC. The design for constructing an integrated nanoelectrospray emitter on the octadecylated silica monolith capillary column was first introduced. In comparison with the separated configuration where the emitter is connect...

متن کامل

Capillary trap column with strong cation-exchange monolith for automated shotgun proteome analysis.

A 150 microm internal diameter capillary monolithic column with a strong cation-exchange stationary phase was prepared by direct in situ polymerization of ethylene glycol methacrylate phosphate and bisacrylamide in a trinary porogenic solvent consisting dimethylsulfoxide, dodecanol, and N,N'-dimethylformamide. This phosphate monolithic column exhibits higher dynamic binding capacity, faster kin...

متن کامل

Automated injection of uncleaned samples using a ten-port switching valve and a strong cation-exchange trap column for proteome analysis.

Nanoliter flow rate is optimum for separation in capillary column liquid chromatography coupled with tandem mass spectrometry (muHPLC-MS/MS). In order to develop a high-performance automated proteome analysis system allowing direct injection sample containing detergents, the influence of void volume varied from 0 to 5 microL on the separation performance and proteomic coverage of sample injecti...

متن کامل

Development of a frit-free SPE-based in-column preconcentration system for capillary electrophoresis.

An in-capillary sample preconcentration strategy based on solid phase extraction (SPE) technology coupled with capillary electrophoresis (CE) has been developed taking advantage of both techniques (SPE and CE). An in-line frit-free preconcentration device for capillary electrophoresis containing MCX beads, obtained from the corresponding Waters OASIS cartridges, was prepared. The retention of t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytica chimica acta

دوره 652 1-2  شماره 

صفحات  -

تاریخ انتشار 2009