Vacuum-Assisted Continuous Circular Capsulorhexis Using Bimanual Irrigation and Aspiration System of Phaco Machine in Immature Cataract
نویسندگان
چکیده
Seventy-eight eye of 65 patients were enrolled in this retrospective clinical study. Two-side ports are made with a 23-gauge stiletto knife. The irrigation handpiece is introduced into the anterior chamber through one side port and 27-gauge cystotome is introduced through the other one. Anterior capsular flap is created with cystotome. The capsular flap is vacuumed with a 25-gauge visco elastic's cannula, which connected to the phaco machine vacuum. The continuous circular capsulorhexis (CCC) is completed with the using bimanual irrigation and aspiration system of phaco machine. Vacuum-assisted CCC technique was used in 78 cases of uncomplicated immature senile cataracts. All cases were done under sub-Tenon's anesthesia. A complete CCC was achieved in all cases. Performing CCC with our technique is easy, safe, and cheap. It may be an alternative method to CCC by using OVD and forceps.
منابع مشابه
Closed chamber globe stabilization and needle capsulorhexis using irrigation hand piece of bimanual irrigation and aspiration system
BACKGROUND The prerequisites for a good capsulorhexis include a deep, well maintained anterior chamber, globe stabilization and globe manipulation. This helps to achieve a capsulorhexis of optimal size, shape and obtain the best possible position for a red glow under retroillumination. We report the use of irrigation handpiece of bimanual irrigation aspiration system to stabilize the globe, mai...
متن کاملViscoless microincision cataract surgery
A cataract surgery technique is described in which incisions, continuous circular capsulorhexis and hydrodissection are made without the use of any viscoelastics. Two small incisions are created through which the different parts of the procedure can take place, maintaining a stable anterior chamber under continuous irrigation. Subsequent bimanual phacoemulsification can be done through these mi...
متن کاملPhaco capsulotomy in intumescent cataract.
Intumescent cataracts are challenging cases even for experienced phaco surgeons (Bhattacharjee et al, 1999; Ermiss et al, 2003). In these eyes, during capsulorhexis, there are very high chances of anterior capsule tears with peripheral extension due to the high pressure of the hydrated cataractous lens. Following this, the continuation of phacoemulsification is extremely difficult and is associ...
متن کاملOptimizing refractive lens exchange with bimanual microincision phacoemulsification.
Bimanual microincision phacoemulsification entails the removal of the crystalline lens through 2 1.2 mm incisions. Infusion is provided through a separate irrigating handpiece, and phacoemulsification and aspiration are performed through a sleeveless phacoemulsification needle. We describe a technique for refractive lens exchange using bimanual microincision phacoemulsification. Capsulorhexis f...
متن کاملManagement of Congenital Cataract Surgery
Congenital cataract surgery is a complex issue best left to surgeons who are familiar with its long-term complications and lengthy follow-up. Treatment is often difficult and tedious and requires a dedicated team effort, the most important members being parents. At one point, lensectomy was the standard treatment used in such cases. However, in recent times, small incisions, anterior capsulorhe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2013 شماره
صفحات -