In-stent neointimal proliferation correlates with the amount of residual plaque burden outside the stent: an intravascular ultrasound study.

نویسندگان

  • F Prati
  • C Di Mario
  • I Moussa
  • B Reimers
  • M T Mallus
  • A Parma
  • E Lioy
  • A Colombo
چکیده

BACKGROUND The aim of this study was to evaluate the relationship between residual plaque burden after coronary stent implantation and the development of late in-stent neointimal proliferation. METHODS AND RESULTS Between January 1996 and May 1997, 50 patients underwent intravascular ultrasound (IVUS) interrogation at 6+/-1.2 months after coronary stent implantation in native coronary arteries. IVUS images were acquired with a motorized pullback, and cross-sectional measurements were performed within the stents at 1-mm intervals. The following measurements were obtained: (1) lumen area (LA), (2) stent area (SA), (3) area delimited by the external elastic membrane (EEMA), (4) percent neointimal area calculated as (SA-LA/SA)x100, and (5) percent residual plaque area calculated as (EEMA-SA)/EEMAx100. Volume measurements within the stented segments were calculated by applying Simpson's rule. In the pooled data analysis of 876 cross sections, linear regression showed a significant positive correlation between percent residual plaque area and percent neointimal area (r=0.50, y= 45.03+0.29x, P<0.01). There was significant incremental increase in mean percent neointimal area for stepwise increase in percent residual plaque area. Mean percent neointimal area was 16.3+/-10.3% for lesions with a percent residual plaque area of <50% and 27.7+/-11% for lesions with a percent residual plaque area of >/=50% (P<0.001). The volumetric analysis showed that the percent residual plaque volume was significantly greater in restenotic lesions compared with nonrestenotic lesions (58.7+/-4.3% versus 51.4+/-5.7%, respectively; P<0.01). CONCLUSIONS Late in-stent neointimal proliferation has a direct correlation with the amount of residual plaque burden after coronary stent implantation, supporting the hypothesis that plaque removal before stent implantation may reduce restenosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Neointimal tissue proliferation after coronary stent implantation without predilatation].

INTRODUCTION AND OBJECTIVES Intravascular ultrasound (IVUS) studies in conventional stent angioplasty with predilatation have demonstrated that late luminal narrowing is caused by neointimal proliferation. In the present study, we analyzed the degree and distribution of in-stent neointimal proliferation after direct stent implantation and aimed to identify variables that predict a proliferative...

متن کامل

Intravascular ultrasound and histology findings in very late bare-metal stent thrombosis.

Very late thrombosis in an implanted bare-metal stent is a very uncommon event outside the context of brachytherapy and few data about its pathophysiology are available. We performed an intravascular ultrasound study during primary angioplasty in five patients with very late bare-metal stent thrombosis and carried out a histological analysis of the material removed by manual thrombectomy. The m...

متن کامل

Novel drug-delivery stent: intravascular ultrasound observations from the first human experience with the QP2-eluting polymer stent system.

BACKGROUND The aim of this study was to use serial intravascular ultrasound (IVUS) to evaluate the long-term effect of stent-based 7-hexanoyltaxol (QP2, a taxane analogue) delivery on neointimal tissue growth within the stent and on vessel dimensions at the adjacent reference segments. METHODS AND RESULTS Serial IVUS analyses (immediately after intervention and at follow-up at 8.3 months) wer...

متن کامل

Characterization of plaque prolapse after drug-eluting stent implantation in diabetic patients: a three-dimensional volumetric intravascular ultrasound outcome study.

OBJECTIVES The aim of this research was to evaluate the plaque prolapse (PP) phenomenon after bare-metal (BMS) and drug-eluting stent (DES) implantation in patients with diabetes mellitus using 3-dimensional volumetric intravascular ultrasound (IVUS). BACKGROUND Plaque prolapse has been observed in up to 22% of patients treated with BMS. Diabetic patients have a larger atherothrombotic burden...

متن کامل

Impact of Polymer Formulations on Neointimal Proliferation After Zotarolimus-Eluting Stent With Different Polymers

Background—Polymer formulation may affect the efficacy of drug-eluting stents. Resolute, Endeavor, and ZoMaxx are zotarolimus-eluting stents with different stent platforms and different polymer coatings and have been tested in clinical trials. The aim of this analysis was to compare the efficacy of zotarolimus-eluting stents with different polymers. Methods and Results—Data were obtained from t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 99 8  شماره 

صفحات  -

تاریخ انتشار 1999