Comparison of HE4, CA125, and ROMA Diagnostic Accuracy
نویسندگان
چکیده
Risk of Ovarian Malignancy Algorithm (ROMA) combing human epididymis secretary protein 4 (HE4) and CA125 showed better diagnostic accuracy for epithelial ovarian cancer (EOC) when compared with HE4 or CA125 alone; however, other studies showed no or worse diagnostic accuracy. We aim to conduct a prospective and multicenter clinical trial to compare the diagnostic accuracy of HE4, CA125, and ROMA for EOC.A prospective and multicenter (n = 9) trial including 2481 individuals was performed in Chinese women. HE4, CA125, and ROMA diagnostic accuracy were evaluated according to different menopausal status and stages of EOC. Their diagnostic values were evaluated by the area under curve (AUC) and compared by the Z scores. Diagnostic specificity of other kinds of participants (n = 1098) was also evaluated.For discriminating between healthy control (HC) and EOC, only CA125 showed significant difference for discriminating HC and EOC in all the individuals when compared with HE4 and ROMA (P < 0.001 and P = 0.02, respectively), at the cutoff value of 31.5, the sensitivity (SN) and specificity (SP) were 88.6% and 97.1%. For discriminating between benign pelvic mass (BPM) and EOC, ROMA showed significant difference for discriminating BPM and EOC in the all individuals (P = 0.01 and P = 0.02, respectively) and the postmenopausal individuals (P = 0.03 and P = 0.04, respectively), at the cutoff value of 27.3 and 34.5, the SNs were 97.0% and 89.4%, SPs were 81.4% and 82.5%, separately. Within all kinds of diseases, there was no significant difference in specificity between CA125 and HE4.In conclusions, when HE4, CA125, and ROMA were compared with each other according to different menopausal status, and stages. Only CA125 showed significant difference for discriminating HC and EOC in all the individuals, and ROMA for discriminating BPM and EOC in the all individuals and postmenopausal individuals when compared with HE4 or CA125. HE4 has showed no significant difference in specificity with all kinds of diseases when compared with CA125.
منابع مشابه
Evaluation of diagnostic accuracy of RMI and ROMA indices in comparison to HE4 and CA125 parameters for estimating the risk of malignancy of adnexal masses.
Background: Ovarian cancer is the fifth leading cancer-related cause of death in women worldwide and is often diagnosed at advanced stages. Regarding the low sensitivity and specificity of the currently available diagnostic techniques, in the present study, we aimed to evaluate the accuracy of RMI and ROMA indexes and comparing these two indexes with CA-125 and HE4 parameters for the diagnosis ...
متن کاملThe diagnostic accuracy of two human epididymis protein 4 (HE4) testing systems in combination with CA125 in the differential diagnosis of ovarian masses.
BACKGROUND Cancer antigen 125 (CA125) is the best known single tumor marker for ovarian cancer (OC). We investigated whether the additional information of the human epididymis protein 4 (HE4) improves diagnostic accuracy. METHODS We retrospectively analyzed preoperative sera of 109 healthy women, 285 patients with benign ovarian masses (cystadenoma: n=78, leimyoma: n=66, endometriosis: n=52, ...
متن کاملComparing the Diagnostic Value of the Risk of Ovarian Malignancy Algorithm and CA125 in Patients with Ovarian Mass
Background and purpose: Ovarian cancer is the fourth leading cause of death from gynecological cancers in women. Using specific tumor markers that help in making diagnosis at early stages improve therapeutic outcomes. The purpose of this study was to evaluate the diagnostic value of the Risk of Ovarian Malignancy Algorithm (ROMA) index in patients with ovarian mass. Materials and methods: A cr...
متن کاملComparison of HE4, CA125, and Risk of Ovarian Malignancy Algorithm in the Prediction of Ovarian Cancer in Korean Women
This study is a multi-center clinical study, which aimed to compare CA125, HE4, and risk of ovarian malignancy algorithm (ROMA) in predicting epithelial ovarian cancer of Korean women with a pelvic mass. Prospectively, serum from 90 Korean women with ovarian mass was obtained prior to surgery. For control group, serum from 79 normal populations without ovarian mass was also obtained. The HE4 an...
متن کاملModification of cutoff values for HE4, CA125, the Risk of Malignancy Index, and the Risk of Malignancy Algorithm for ovarian cancer detection in Jakarta, Indonesia.
BACKGROUND CA125 and HE4 are used in calculating Risk of Malignancy Algorithm (ROMA); and Risk of Malignancy Index (RMI). However, studies showed that normal levels of CA125, and HE4 differ among ethnicities such as between Asians and Caucasians, thus affecting the accuracy of the RMI score and ROMA in predicting ovarian malignancy. This study aimed to determine whether new or modified cutoff v...
متن کامل