Improving limited-view photoacoustic tomography with an acoustic reflector.

نویسندگان

  • Bin Huang
  • Jun Xia
  • Konstantin Maslov
  • Lihong V Wang
چکیده

The versatility and real-time imaging capability of commercial linear array transducers make them widely used in clinical ultrasound and photoacoustic imaging. However, they often suffer from limited detection view. For instance, acoustic waves traveling at a grazing angle to the transducer surface are difficult to detect. In this letter, we propose a simple and easy approach to ameliorate this problem by using a 45-deg acoustic reflector. The reflector forms a virtual array that is perpendicular to the physical array, thereby doubling the detection coverage. The improvement in image quality in photoacoustic tomography was demonstrated through a hair phantom, a leaf skeleton phantom, and an ex vivo mouse ear experiment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tripling the detection view of high-frequency linear-array-based photoacoustic computed tomography by using two planar acoustic reflectors.

BACKGROUND Linear-array-based photoacoustic computed tomography (PACT) suffers from a limited view. Circular scanning does increase the detection view angle but is time-consuming. Therefore, it is desirable to increase the detection view angle of linear-array-based PACT without sacrificing imaging speed. METHODS Two planar acoustic reflectors placed at 120 degrees to each other were added to ...

متن کامل

Multi-source Quantitative Photoacoustic Tomography with Detector Response Function and Limited-view Scanning

A practical image reconstruction method for multi-source quantitative photoacoustic tomography (QPAT) is proposed in this work with the consideration of detector response function and limited-view scanning. First, the correct detector response function, i.e., spatial impulse response (SIR) and acousto-electric impulse response (EIR), is considered for the ultrasonic transducer to accurately mod...

متن کامل

Improving Photoacoustic Inversion on Parabolas

Photoacoustic tomography (PAT) is a novel tomographic imaging paradigm that combines the benefits of ultrasound imaging and optical tomography [8]. When a semitransparent sample is illuminated with a short pulse of electromagnetic energy, then parts of the optical energy become absorbed which in turn induces an acoustic pressure wave inside the sample (see Figure 1.1). The induced acoustic pres...

متن کامل

The use of acoustic reflectors to enlarge the effective area of planar sensor arrays

Planar sensor arrays have many advantages including ease of manufacture and low cost. However, when used for photoacoustic (PA) imaging, planar sensors have a limited view of the acoustic field, which means some of the waves from the PA source are not recorded. This results in artifacts in the reconstructed image of the PA source (the initial acoustic pressure distribution). In this paper, we d...

متن کامل

Experimental evaluation of reconstruction algorithms for limited view photoacoustic tomography with line detectors

A method for photoacoustic tomography is presented that uses line integrals over the acoustic wave field from a photoacoustic source for the reconstruction of a three-dimensional image. The line integrals are acquired with an optical line sensor based on a Mach–Zehnder interferometer. Image reconstruction is a two-step process. In the first step data from a scan of the line outside the object a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical optics

دوره 18 11  شماره 

صفحات  -

تاریخ انتشار 2013