Minute pattern of human perspiration observed by a continuously recording method.

نویسندگان

  • T NAKAYAMA
  • K TAKAGI
چکیده

Attempts were made by Yen, and more successfully by Takahara (see 5, 6) to observe continuously the discharge of sweat from a single human sweat gland. A capillary glass tube was inserted into a sweat pore and the movement of the sweat column therein accumulated was recorded. This method is very difficult because the sweat duct runs through the epidermis in cork-screw fashion. Furthermore, the application of this method is limited to the palm. Starch paper method introduced by Randall (7) demonstrated a periodic output of sweat. Starch paper, however, must have been attached to the skin for more than 15sec., which unabled to observe the variation of sweating that might occur during the time. The procedure adopted by Kuno (5) for the estimation of the amount of sweat was as follows:dry air was allowed to pass through the celluloid dish (20cm.2) adhered to the skin tightly with collodion, was charged thereby with moisture given off from the skin and was led into small U-tubes containing calcium chloride. This method can only observe changes in sweat secretion per unit of 5min. In the present study, instead of the absorption of water vapor, a sensitive resistance hygrometer was employed enabling a continuous recording of sweating. The hemihidrotic reflex due to postural changes, first described by Kuno (5) was clearly explained by one of the authors to be a consequence of pressure applied on the skin (8). Recently, Watkins (9) tested the effect of pressure on sweating and obtained completely different results denying the presence of the pressure-sweating reflex. More recently, however, the hemihidrotic reflex has been reconfirmed by Ferres (3). With this state of affairs, the effect of pressure on sweating was again investigated using the new method described in this paper.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Differential Method for Recording the Rate of Water Evaporation in a Small Skin Area.

Continuous recording of water discharge from the skin in its detailed figure of fluctuations was often taken as necessary for investigation of cutaneous perspiration. Though there have been hitherto reported so many methods for measurement of water evaporation from a small skin area, most of them are for discontinuous estimation of it. As far as continuous or semi-continuous recordings are conc...

متن کامل

Reviewing the physiology of human perspiration and introducing different types of antiperspirant and deodorant products

Habits since the introduction of the first commercial antiperspirant and deodorant, the use of these products have played an increasing role in a person's personal care. This article studies the physiology of human perspiration and responsible compounds for body odor. It also describes the function, classification, and differences between antiperspirants and deodorants.

متن کامل

Molecular Identification and Antibacterial Drug Resistance Pattern of Staphylococcus Aureus Isolated in Rasht, Iran

Abstract Background and Objective: Staphylococcus aureus is an important opportunistic pathogen causing a wide range of infections in human .Most clinical isolates of S.aureus are resistant to a number of antibiotics. For appropriate antimicrobial therapy, this study was conducted to determine antibacterial drug resistance patterns of S.aureus isolates obtained from different clinical samp...

متن کامل

Characterization, Similarity Score and Uniqueness Associated with Perspiration Pattern

Vulnerabilities in biometric systems including spoofing has emerged as an important issue. The focus of this work is on characterization of ‘perspiration pattern’ in a time-series of fingerprint images for liveness detection. By using information in the high pass bands of the images the similarity score for the two images is calculated to determine the uniqueness of the perspiration pattern. In...

متن کامل

سنجش عملکرد سامانه‌های رابط مغز و رایانه P300 Speller به‌ازای ماتریس نمایش ردیف و یا ستون (RCP) و نمایش حروف زبان فارسی

As a Brain computer interface system, BCI P300 Speller tries to help disabled people and patients to regain some of their lost ability with allowing communication via typing. The ability of personalization is one of the most important features in a BCI system, so the typing language as a personalization factor is an important feature in a BCI speller. Most prior researches on P300 Speller has f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Japanese journal of physiology

دوره 9  شماره 

صفحات  -

تاریخ انتشار 1959