[Analysis of photonuclear activation effect of high-energy medical linear accelerators--measurement of spatial dose distribution and temporal decay curve, and assessment of personnel dosimetry].

نویسندگان

  • Hiroshi Fukuma
  • Yuta Eguchi
  • Shigeru Isoyama
  • Makoto Kawano
  • Yusuke Suzuki
  • Takahiro Aoyama
  • Hideki Kato
چکیده

The characteristics of activation after high-energy X-rays have been generated by medical linear accelerators were measured using an ionization chamber. Radiation doses increased with rising X-ray energy, based on 10 MV, 15 MV, and 18 MVX-ray measurements. When the total irradiation dose was changed, radiation dose increased with total irradiation dose. When the collimator opened, the radiation dose at a position 15 cm from the isocenter reached about the maximum, which was 2.2 times the dose at the isocenter. The radiation dose became about 0.3 times its level at a position 40 cm from the isocenter, in the outer irradiation field. The dose distribution in the treatment room became almost the same dose extending from the isocenter to 200 cm. Radiation dose decreased gradually while moving away from the target on the treatment beam axis. But it increased again as it approached the floor face. The occupational exposure dose, which was presumed from measurements of the radiation dose 50 cm from the isocenter, was about 0.9 mSv during a year, assuming 600 MU for 1 person, 8 people a day, and 245 days a year. Radiation dose changed with X-ray energy in the machine used, and it was a geometrical constituent in the treatment room. It is important to understand the characteristics of radiation generated by medical linear accelerators.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The dosimetry assessment of Varian Linear Accelerators of 6, 15 and 20 MV by Monte Carlo Method

 Introduction: Monte Carlo method is often applied in radiation therapy as utilized in all the branches of science. An important requirement for successful radiotherapy is carefully examine the dose distribution specifications and decrease the difference between these features with experience to an acceptable level. In this study, the characteristics of 6, 15 and 20 MeV incident x-rays are prov...

متن کامل

Unexpected dose and the biological effect of neutron contamination in linear accelerators

Employing High-energy photons in medical linear accelerators can lead to neutron contamination. The relative biological effect of neutrons is 20 times higher than photons. Consequently, its damage to the biological tissue is much higher and unobtrusive. In this study, we calculated neutron equivalent dose in a medical linear accelerator by the FLUKA Monte Carlo code system. The results show tha...

متن کامل

A study on needed or unneeded ReDosimetry and Recomissioning of a linac with Add on MLC by Comparing Dosimetric Data

Introduction: Today different uses of multileaf collimators(MLC) in different techniques of radiotherapy are common. Due to the use of this facility it is possible to have maximum radiation dose to target volumes and minimum radiation dose to critical tissues surronding treatment volumes. But there are numerouse Linear accelerators in IRAN without MLC. Because of high price of...

متن کامل

Comparing experimental assessment of the peripheral dose outside the applicator in electron beams of ELEKTA with Treatment planning system

Introduction: The use of electrons in the electron therapy to destroy tumoral tissue is dedicated significant contribution of different methods of radiation therapy. Scattered radiation due to exited electrons of the applicator affect the dose out of the field in the patient's normal tissue. The aim of this study is to determine the peripheral dose outside the applicator in the...

متن کامل

Total skin electron therapy (TSET): Monte Carlo Simulation and implementation

Introduction: Total skin electron irradiation technique is used in treatment of the mycosis fungoid. The implementation of this technique requires non-standard measurements and complex dosimetry methods. Operating procedures for total skin electron irradiation and its dosimetry vary in different radiation therapy centers in the world. In this article, validation of TSET techniq...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nihon Hoshasen Gijutsu Gakkai zasshi

دوره 66 5  شماره 

صفحات  -

تاریخ انتشار 2010