Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO-2) trial.
نویسندگان
چکیده
OBJECTIVES We tested the hypothesis that thinner-strut stents are associated with a reduced rate of restenosis when comparing two stents with different design. BACKGROUND We have previously shown that, for two stents with similar design, the risk for restenosis is dependent on the strut thickness. It is unknown whether strut thickness preserves its relevance as a determinant of restenosis even in the presence of different stent designs. METHODS A total of 611 patients with symptomatic coronary artery disease were randomly assigned to receive either the thin-strut ACS RX Multilink stent (Guidant, Advanced Cardiovascular Systems, Santa Clara, California) (strut thickness 50 microm, interconnected ring design; n = 309) or the thick-strut BX Velocity stent (Cordis Corp., Miami, Florida) (strut thickness 140 microm, closed cell design; n = 302). The primary end point was angiographic restenosis (> or =50% diameter stenosis at follow-up angiography). Secondary end points were the incidence of target-vessel revascularization (TVR) and the combined rate of death and myocardial infarction (MI) at one year. RESULTS The incidence of angiographic restenosis was 17.9% in the thin-strut group and 31.4% in the thick-strut group, relative risk, 0.57 (95% confidence interval, 0.39 to 0.84), p < 0.001. A TVR due to restenosis was required in 12.3% of the thin-strut group and 21.9% of the thick-strut group, relative risk, 0.56 (95% confidence interval, 0.38 to 0.84), p = 0.002. No significant difference was observed in the combined incidence of death and MI at one year. CONCLUSIONS When two stents with different design are compared, the stent with thinner struts elicits less angiographic and clinical restenosis than the thicker-strut stent.
منابع مشابه
Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO) trial.
BACKGROUND Increased thrombogenicity and smooth muscle cell proliferative response induced by the metal struts compromise the advantages of coronary stenting. The objective of this randomized, multicenter study was to assess whether a reduced strut thickness of coronary stents is associated with improved follow-up angiographic and clinical results. METHODS AND RESULTS A total of 651 patients ...
متن کاملEffect of glycoprotein IIb/IIIa receptor blockade with abciximab on clinical and angiographic restenosis rate after the placement of coronary stents following acute myocardial infarction.
OBJECTIVES In the Intracoronary Stenting and Antithrombotic Regimen-2 trial (ISAR-2), we sought to investigate the effect of abciximab on angiographic and clinical restenosis after stenting following acute myocardial infarction (AMI). We also intended to assess the impact of abciximab on clinical outcome in this setting. BACKGROUND It is unclear whether abciximab reduces neointima formation a...
متن کاملUltrasound-guided strategy for provisional stenting with focal balloon combination catheter: results from the randomized Strategy for Intracoronary Ultrasound-guided PTCA and Stenting (SIPS) trial.
BACKGROUND Intracoronary ultrasound (ICUS) has provided insights into vascular pathology and interventional therapy. The Strategy for ICUS-Guided PTCA and Stenting (SIPS) trial tested the hypothesis that routine ICUS guidance of coronary interventions improves outcome. METHODS AND RESULTS A single-center consecutive-patient randomized design (with 6-month angiographic and 2-year clinical foll...
متن کاملThe need for stent-lesion matching to optimize outcomes of intracoronary stent implantation.
Intracoronary stents have markedly improved the outcomes of catheter-based coronary interventions. Intracoronary stent implantation rates of over 90% during coronary angioplasty are common. Stent implantations are associated with a small but statistically significant number of adverse outcomes including restenosis, thrombosis, strut malapposition, incomplete strut endothelialization, and variou...
متن کاملIntracoronary ultrasound-guided stenting improves outcomes: a meta-analysis of randomized trials.
BACKGROUND Intracoronary ultrasound (IVUS) has been used as an adjunctive method in order to optimize implantation of stents. However, the impact of this method in some outcomes is controversial. OBJECTIVE To systematically review the impact of routine IVUS-guided coronary stent as compared to angiographic-guided, on clinical and angiographic outcomes. METHODS A search of databases (MEDLINE...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Cardiology
دوره 41 8 شماره
صفحات -
تاریخ انتشار 2003