Endoscopic removal of buried lumen-apposing metal stents used for cystogastrostomy and cholecystogastrostomy.
نویسندگان
چکیده
The Hot AXIOS system is a new device for transgastric or transduodenal endoscopic drainage of a pancreatic pseudocyst or the gallbladder [1,2] using a lumen-apposing metal stent (LAMS) mounted on an electrocautery-enhanced introduction system. The device seems to be relatively safe in expert hands; however, the literature on management of its complications is limited [1–4]. Hereby, we report on two patients with embedded LAMSs, which were endoscopically removed. Patient 1 was a 68-year-old man with a pseudocyst after acute pancreatitis who underwent successful endoscopic ultrasound (EUS)-guided cystogastrostomy with placement of an AXIOS stent (10× 10mm). Endoscopic removal of the LAMS was planned 3 months later; however, gastroscopy showed tissue overgrowth at the gastric flange of the LAMS making direct removal of the stent with a rat-tooth forceps or snare impossible. To avoid the patient having to undergo surgery, we opted for endoscopic treatment consisting of forced argon plasma coagulation (APC), needle-knife incision, and dilation of the stent up to 12mm (●" Video 1). After the tissue overgrowth had been sufficiently removed from the gastric flange, it was possible to remove the LAMS with a rattooth forceps. No complications subsequently occurred. Patient 2 was a 59-year-old man with acute acalculous cholecystitis who underwent successful endoscopic gallbladder drainage by EUS-guided cholecystogastrostomy using a 15×10-mm AXIOS stent. LAMS removal was performed after 4 months. At gastroscopy, we found a buried gastric flange of the LAMS (●" Fig.1) in the antrum. Because standard stent removal with forceps was impossible, we dilated the LAMS up to 15mmwith a balloon, entered it with the endoscope, and removed the stent inside-out with a rat-tooth forceps. No complications subsequently occurred. Both these clinical cases show that tissue overgrowth at the gastric side of a LAMS can be a complication after cystogastrostomy and cholecystogastrostomy, making regular stent removal with a forceps impossible [1,3]. In such circumstances, endoscopic techniques as described above can be considered as rescue therapy.
منابع مشابه
The buried stent: a rare complication of endoscopic ultrasound-guided pancreatic necrosectomy using a lumen-apposing metal stent.
A 51-year-old man was referred to our facility for endoscopic ultrasound-guided drainage of walled-off pancreatic necrosis. The cyst was first punctured with a 19-gauge needle (▶Fig. 1). A NAGI stent (Taewoong Medical, Seoul, South Korea) was then deployed under ultrasonographic and fluoroscopic guidance without difficulty (▶Fig. 2, ▶Video1). A computed tomography (CT) scan 6 weeks later reveal...
متن کاملPediatric application of a lumen-apposing metal stent for transgastric pancreatic abscess drainage and subsequent necrosectomy.
A 14-year-old boy presented to our care with severe necrotizing pancreatitis secondary to a psychiatric medication. He had developed walled-off pancreas necrosis (WOPN) in the body of the pancreas that had become infected, as evidenced by air within a 10-cm collection on computed tomography (CT) scanning, fevers to 102°F, tachycardia, and leukocytosis. The CT scan showed the collection had a ma...
متن کاملLumen-apposing metal stents (LAMS) for pancreatic fluid collection (PFC) drainage: may not be business as usual
MESSAGE Lumen-apposing metal stents (LAMS) have been recently developed to improve treatment outcomes in the endoscopic management of pancreatic fluid collections (PFC), particularly in walled-off necrosis (WON), to facilitate better drainage of necrotic contents and minimise the risk of perforation and peritoneal leakage. In an ongoing randomised trial, we observed serious adverse events that ...
متن کاملPancreatic Pseudocyst Drainage Using Lumen-Apposing Metal Stents.
MK Currently, the most common approach is with endoscopic ultrasound (EUS) guidance. Using EUS with a large working channel, the endoscopist can puncture and then drain the fluid collection after checking local vasculature with Doppler ultrasound. The drainage will depend on the type of fluid collection. For example, if the patient has a simple pseudocyst, the endoscopist could place a single 1...
متن کاملLumen-apposing covered self-expanding metal stent for management of benign gastrointestinal strictures
BACKGROUND AND AIMS Self-expanding metal stents (SEMS) are safe and effective for endoscopic management of malignant gastrointestinal strictures, but there is limited experience with their use in refractory benign strictures. We assessed the use of a new lumen-apposing covered SEMS for the management of benign gastrointestinal strictures. METHODS A single-center case-series of five patients w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Endoscopy
دوره 48 Suppl 1 شماره
صفحات -
تاریخ انتشار 2016