Dosimetric dependence of the dimensional characteristics on a lead shield in electron radiotherapy: a Monte Carlo study

نویسندگان

  • James C L Chow
  • Grigor N Grigorov
چکیده

This study investigates the dosimetric dependence of the dimension of a lead (Pb) layer for shielding using clinical electron beams with different energies. Monte Carlo simulations were used to generate phase space files of the 4, 9 and 16 MeV electron beams produced by a Varian 21 EX linear accelerator using the EGSnrc-based BEAMnrc code, and validated by measurements using films. Pb layers with different thicknesses (2, 4, 6 and 8 mm) and diameters (2.5, 3, 3.5 and 4 cm) were placed at the center of an electron field on a Solid Water phantom. Beam profiles were determined at the depth of maximum dose (d(m)) using Monte Carlo simulations. The line doses under the Pb layer at d(m) including the penumbra at the edge of the layer and relative dose at the central beam axis (CAX) were studied with varying thickness and diameter of the layer. It is found that 2 mm of Pb layer is adequate to provide 5 half value layer (HVL) attenuation for the 4 MeV electron beams, and the beam profiles at dm under the Pb layer depend on the diameter but the thickness of the Pb. However, for the 9 and 16 MeV electron beams, the relative dose at the CAX and dm depends on both the thickness and diameter of the Pb layer. For 8 mm thickness of Pb, 4 and 5 HVL attenuation of electron beams with energies of 9 and 16 MeV can be achieved at d(m), respectively. Moreover, the beam profile under the Pb layer at dm depends on (1) the penumbra region at the edge of the Pb layer, (2) the beam attenuation varying with the thickness of the Pb layer, (3) the electron side scatter contributing to the CAX under the Pb layer, and (4) the photon contamination produced by the Pb layer. A parameter called "shielding area factor", defined as the ratio of the length between two points of 50% relative doses in the beam profile at dm to the diameter of the Pb layer, is suggested to the radiation oncology staff to predict the required size and thickness of Pb for shielding a target with known dimension at d(m). The dosimetric data calculated by Monte Carlo simulations in this study is useful to select what thickness and size of Pb are suitable for the protection of critical tissue in electron radiotherapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

شبیه‌سازی شتاب‌ دهنده پرتو درمانی حین عمل LIAC به همراه اپلیکاتور شکل دهنده باریکه بااستفاده از محاسبات مونت‌کارلو

Intraoperative electron radiotherapy is one of the radiotherapy methods that delivers a high single fraction of radiation dose to the patient in one session during the surgery. Beam shaper applicator is one of the applicators that is recently employed with this radiotherapy method. This applicator has a considerable application in treatment of large tumors. In this study, the dosimetric charact...

متن کامل

Evaluation putty metal as internal shield for patient protection of electron therapy by Monte Carlo study

Introduction: In this study, a specific combination (70% W 18.61% Ni and 11.39% C) of lead free and flexible putty metal is introduced and validated as internal shielding by Mont Carlo study Materials and Methods: To evaluate putty metal as an internal shielding by Mont Carlo study Varian 2100 C/D was validated within measurement and then by given energy spect...

متن کامل

Investigation of the dose enhancement effect due to gold nanoparticles at 18 MV radiotherapy using MAGIC-f and Monte Carlo methods Thoraco-Lumbar spinal cord fMRI in 3T Magnetic field

Introduction: Normoxic MAGIC-f polymer gels are established dosimeters used for three dimensional dos uantifications in radiotherapy. The high atomic number nanoparticles such as gold are nov adiosensitizers used to enhance doses delivered to tumors. The aim of this study was t vestigate the effect of gold nanoparticles (GNPs) in enhancing percentage depth doses (PDD ithin the...

متن کامل

Enhancement of the Dose on 12 MV Linac with Free Flattening Filter Mode

Purpose: In the last years, some studies investigated dosimetric benefits of a free flattening filter for the photon mode in the radiotherapy field. This study aims to provide a theoretical study published and analysis of basic dosimetric properties for a Saturne 43 Linac head to implement free flattening filter beams clinically. Material and Methods: Thi...

متن کامل

A Monte Carlo simulation study on the effectiveness of electron filters designed for telecobalt radiation therapy treatment

Background: The aim of present study was to analyze the effectiveness of electron filters in the Telecobalt radiotherapy treatment by simulation technique.  Materials and Methods: The BEAMnrc Monte Carlo code was used to simulate the electron filters of thickness of 0.5 gm/cm2 below the trimmer bar for 35 × 35 cm2 field size in Theratron Equinox-80 telecobalt unit. The electron filters were mad...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2009