Relationship of Annular Sizing Using Multidetector Computed Tomographic Imaging and Clinical Outcomes After Self-Expanding CoreValve Transcatheter Aortic Valve Replacement.

نویسندگان

  • Jeffrey J Popma
  • Thomas G Gleason
  • Steven J Yakubov
  • J Kevin Harrison
  • John K Forrest
  • Brijeshwar Maini
  • Carlos E Ruiz
  • Duane S Pinto
  • Marco Costa
  • Jon Resar
  • John Conte
  • Juan Crestanello
  • Yanping Chang
  • Jae K Oh
  • Michael J Reardon
  • David H Adams
چکیده

BACKGROUND Multidetector computed tomography is useful for determining the appropriate transcatheter heart valve (THV) size in patients with severe aortic stenosis who are suboptimal surgical candidates. The relationship between adherence to the recommended CoreValve sizing algorithm and clinical outcomes is not known. METHODS AND RESULTS We evaluated 1023 patients with severe aortic stenosis deemed high or extreme risk for surgery treated with the CoreValve THV. All patients underwent preprocedural multidetector computed tomography, and the scans were reviewed at a central analysis center using standardized software. Compliance to a recommended sizing algorithm was used to identify patients with below-range, in-range, and above-range THV sizing. A device annular sizing ratio (DAR) was also calculated based on the native annulus perimeter and perimeter of the selected THV. Clinical end points included the presence of paravalvular aortic regurgitation evaluated by an independent echocardiographic laboratory. Adherence to the sizing algorithm was highest with a 31-mm THV (92.6%) and lowest with the 23-mm THV (38.5%). Below-range sizing was associated with a higher rate of moderate or severe paravalvular aortic regurgitation (15.3%) than in-range (6.5%) or above-range (10.0%; P<0.001) sizing. Higher DARs were associated with lower rates of moderate or severe paravalvular aortic regurgitation: DAR ≤10%, 17.6%; DAR 10% to 15%, 9.9%; DAR 15% to 20%, 6.3%; and DAR >20%, 4.9%; P<0.001. There was no increase in clinical events associated with higher DARs. CONCLUSIONS Adherence to a sizing algorithm guided by multidetector computed tomography resulted in lower rates of paravalvular aortic regurgitation after self-expanding transcatheter valve replacement without an increase in complications. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT01240902.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Is time of renal hypoperfusion an important variable in determining response to renal artery revascularization?

3. Gurvitch R, Webb JG, Yuan R, et al. Aortic annulus diameter determination by multidetector computed tomography: reproducibility, applicability, and implications for transcatheter aortic valve implantation. J Am Coll Cardiol Intv 2011;4:1235–45. 4. Achenbach S, Delgado V, Hausleiter J, Schoenhagen P, Min JK, Leipsic JA. SCCT expert consensus document on computed tomography imaging before tran...

متن کامل

FDG-PET/CT for driveline infection in a patient with implantable left ventricular assist device.

can Society of Echocardiography Council for Intraoperative Echocardiography and the Society of Cardiovascular Anesthesiologists Task Force for Certification in Perioperative Transesophageal Echocardiography. J Am Soc Echocardiogr 1999;12: 884–900. 21. Wong DT, Bertaso AG, Liew GY, Thomson VS, Cunnington MS, Richardson JD et al. Relationship of aortic annular eccentricity and paravalvular regurg...

متن کامل

Multimodality Imaging in Transcatheter Mitral Interventions

Both echocardiography (specifically transesophageal echocardiography [TEE]) and multidetector row computed tomography (MDCT) have played an integral role in preprocedural planning for transcatheter aortic valve replacement, heavily influencing the moniker of “multimodality imaging.” The strengths of each modalities are complementary (Table), although there is overlap between the preprocedural a...

متن کامل

Transcatheter aortic valve replacement with the SAPIEN 3: a new balloon-expandable transcatheter heart valve.

OBJECTIVES The aim of this study was to demonstrate the first-in-human feasibility and short-term clinical outcomes with a new balloon-expandable transcatheter heart valve (THV). BACKGROUND The SAPIEN 3 (S3) THV incorporates a paravalvular sealing system, an active 3-dimensional coaxial positioning catheter, and is compatible with a 14-F expandable sheath. METHODS The S3 THV was implanted i...

متن کامل

Relationship of aortic annular eccentricity and paravalvular regurgitation post transcatheter aortic valve implantation with CoreValve.

BACKGROUND Significant paravalvular aortic regurgitation (PAR) after transcatheter aortic valve implantation (TAVI) is associated with negative clinical consequences. We hypothesize that increased eccentricity of the aortic annulus is associated with greater PAR. METHODS Patients with severe aortic stenosis underwent multidetector computed tomography (MDCT) before successful TAVI with the Med...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular interventions

دوره 9 7  شماره 

صفحات  -

تاریخ انتشار 2016