Does setup on rectal wall improve rectal cancer boost radiotherapy?

نویسندگان

  • Jean-Paul J E Kleijnen
  • Bram van Asselen
  • Martijn Intven
  • Johannes P M Burbach
  • Marielle E P Philippens
  • Jan J W Lagendijk
  • Bas W Raaymakers
چکیده

BACKGROUND Rectal cancer patients that show a pathological complete response (pCR) after neo-adjuvant chemo-radiotherapy, have better prognosis. To increase pCR rates several studies escalate the tumor irradiation dose. However, due to lacking tumor contrast on online imaging techniques, no direct tumor setup can be performed and large boost margins are needed to ensure tumor coverage. The purpose of this study was to evaluate the feasibility of performing a setup on rectal wall for rectal cancer boost radiotherapy, thereby using rectal wall nearby the tumor as tumor position surrogate. METHODS For sixteen patients, daily MRI's were performed during 1 week of radiotherapy. On each of these images, tumor and rectum were delineated. Residual displacements were determined per surface voxel after setup on bony anatomy or nearby rectal wall and setup errors for both setups were compared. Furthermore for every rectal wall voxel nearby the tumor, displacement was compared with the closest tumor point and correlation was determined. RESULTS Mean (SD) setup error was 2.7 mm (3.3 mm) and 2.2 mm (3.2 mm) after setup on bony anatomy and rectal wall respectively. Nevertheless, similar PTV-margin estimates i.e. 95th percentile distances, were found; 8.0 mm. Also, a merely moderate correlation; ρ = 0.66 was found between rectal wall and tumor displacement. Further investigation into tumor and rectal mobility differences showed that the rectal wall lacks appropriate anatomical landmarks to find true displacements, especially to capture motion along the rectal wall. CONCLUSIONS Setup on rectal wall slightly reduces mean setup errors but requires a similar PTV-margin as compared to setup on bony anatomy. Rectal mobility might be similar to tumor mobility, but due the absence of anatomical landmarks in the rectum, displacements along the rectal wall are not detected on current online imaging. Therefore, to further reduce tumor position uncertainties, direct or indirect online tumor visualization is needed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of Rectal Retractor, a rectal protector on rectal dose in radical prostate radiotherapy

Introduction: The close proximity of the rectum tissue to the prostate gland results in rectal toxicity during prostate radiotherapy. Rectal Retractor (RR) is a rectal displacement technique that inserts into the rectum, as a result, the lateral and dorsal part of the rectal wall push away from high dose areas. The aim of this study was to investigate the dosimetric consequence...

متن کامل

Prostate IMRT: Two-dimensional model of rectal NTCP employing the variability of rectal motion and rectum wall thickness

Background: In order to improve the evaluation of possible rectal toxicity based on the rectal normal tissue complication probability (NTCP), we consider the fractional dependence of the NTCP on the wall thickness (tW) and rectal displacement (RM). Materials and Methods: The two-dimensional NTCP model (NTCP2D) was developed using radiotherapy plans of ten randomly selected patients with prostat...

متن کامل

Rectal wall dose estimation in intracavitary brachytherapy: A preliminary comparison of an in-house rectal wire versus ICRU 38 recommendations

Background: In intracavitary brachytherapy for gynecological cancers, various techniques are used to locate the anterior rectal wall nearest to the sources but there is no consensus on the best method to do so. This study aimed to compare a technique used routinely in some centers that employs a wire marker to locate the position of the maximum rectal dose point, versus the method recommended b...

متن کامل

Radiomics modelling of IMRT induced acute rectal toxicity using clinical and magnetic resonance imaging features

Introduction: Rectal toxicity is a dose limiting issue in prostate cancer radiotherapy. Prediction of these effects may be used to tailor the therapy. The purpose of this work was to develop predictive radiomic models based on clinical, dosimetric and radiomic features extracted from rectal wall magnetic resonance image (MRI).   Materials and Methods: This st...

متن کامل

Real-time in vivo rectal wall dosimetry using MOSkin detectors during linac based stereotactic radiotherapy with rectal displacement

BACKGROUND MOSFET dosimetry is a method that has been used to measure in-vivo doses during brachytherapy treatments and during linac based radiotherapy treatment. Rectal displacement devices (RDDs) allow for safe dose escalation for prostate cancer treatment. This study used dual MOSkin detectors to assess real-time in vivo rectal wall dose in patients with an RDD in place during a high dose pr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiation oncology

دوره 13 1  شماره 

صفحات  -

تاریخ انتشار 2018