Induction of Monocular Stereopsis by Altering Focus Distance: A Test of Ames’s Hypothesis

نویسنده

  • Dhanraj Vishwanath
چکیده

Viewing a real three-dimensional scene or a stereoscopic image with both eyes generates a vivid phenomenal impression of depth known as stereopsis. Numerous reports have highlighted the fact that an impression of stereopsis can be induced in the absence of binocular disparity. A method claimed by Ames (1925) involved altering accommodative (focus) distance while monocularly viewing a picture. This claim was tested on naïve observers using a method inspired by the observations of Gogel and Ogle on the equidistance tendency. Consistent with Ames's claim, most observers reported that the focus manipulation induced an impression of stereopsis comparable to that obtained by monocular-aperture viewing.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ارزیابی تغییرات دید عمق دور افراد نرمال در اثر هتروفوریای ایجاد شده به‌وسیله‌ی تست سه میله

Backgrounds and Objective: Stereoacuity is due to a relative difference between images because of retinal disparity. Measurment of stereoacuity is important for diagnosis and treatment of binocular anomalies and noerological problems. The aim of this study was to determine the effect of induced heterophoria by base-out and base-in prisms on distance stereopsis by the Three Needle Test. Material...

متن کامل

Enhanced Monocular Visual Odometry Integrated with Laser Distance Meter for Astronaut Navigation

Visual odometry provides astronauts with accurate knowledge of their position and orientation. Wearable astronaut navigation systems should be simple and compact. Therefore, monocular vision methods are preferred over stereo vision systems, commonly used in mobile robots. However, the projective nature of monocular visual odometry causes a scale ambiguity problem. In this paper, we focus on the...

متن کامل

Contribution of a Real Depth Distance Stereoacuity Test to Clinical Management

Measurement of Stereopsis forms an important part of the clinical assessment of patients with disorders of ocular motility. The introduction of a real depth distance stereoacuity test (FD2) was evaluated in clinical practice and to what extent the introduction affected clinical management. Seventy-three patients under evaluation before and following the introduction of the test were included. C...

متن کامل

The role of transparency in da Vinci stereopsis

The majority of natural scenes contains zones that are visible to one eye only. Past studies have shown that these monocular regions can be seen at a precise depth even though there are no binocular disparities that uniquely constrain their locations in depth. In the so-called da Vinci stereopsis configuration, the monocular region is a vertical line placed next to a binocular rectangular occlu...

متن کامل

Monocular blur alters the tuning characteristics of stereopsis for spatial frequency and size

Our sense of depth perception is mediated by spatial filters at different scales in the visual brain; low spatial frequency channels provide the basis for coarse stereopsis, whereas high spatial frequency channels provide for fine stereopsis. It is well established that monocular blurring of vision results in decreased stereoacuity. However, previous studies have used tests that are broadband i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2016