A comparison of the random-zero and standard mercury sphygmomanometers.

نویسندگان

  • D Parker
  • K Liu
  • A R Dyer
  • D Giumetti
  • Y L Liao
  • J Stamler
چکیده

Both the standard mercury sphygmomanometer and the random-zero sphygmomanometer have been used in epidemiological studies and clinical trials. Problems arise in comparing studies since, in addition to other methodological differences, the readings obtained with the random-zero sphygmomanometer have been found to be lower than those obtained with the standard mercury sphygmomanometer. In the present study, blood pressures were measured in 66 subjects to examine the comparability of findings with the two instruments. Trained observers measured blood pressures simultaneously using a double-headed stethoscope and one cuff connected to the two sphygmomanometers. Use of instrument was randomly assigned for each blood pressure measurement; each observer was unaware of the other's blood pressure reading. Readings were lower with the random-zero sphygmomanometer; mean difference ranged from 2.5 to 3.3 mm Hg for systolic pressure and 1.9 to 2.7 mm Hg for diastolic pressure. Digit distributions recorded by the two observers for the standard mercury sphygmomanometer and the random-zero sphygmomanometer were not significantly different for either systolic or diastolic blood pressure. Intraindividual variation was greater with the random-zero sphygmomanometer than with the standard mercury sphygmomanometer. These data do not indicate that one instrument is clearly superior to the other, although in studies where the observer seeks to reduce the bias of multiple readings per person, the random-zero sphygmomanometer may be the more appropriate instrument. Critical to the use of either instrument are careful training, standardization, certification, and periodic recertification of observers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical evaluation of the Infrasonde D4000 blood pressure monitor.

Choosing a blood pressure machine from their ever increasing number is often difficult due to lack of performance data. We have evaluated a new automated non-invasive blood pressure recorder, the Infrasonde D4000. In comparison with the Hawksley random zero mercury sphygmomanometer the Infrasonde showed less variability for both systolic and diastolic readings. However, it was found to record s...

متن کامل

Properties of the random zero sphygmomanometer.

The random zero sphygmomanometer is widely used in studies involving blood pressure measurement because it is believed to eliminate digit preference and reduce measurement error. We performed blood pressure measurements sequentially using random zero and standard sphygmomanometers in random order in 1,356 participants in the Cardiovascular Health Study. Despite adherence to the manufacturer's i...

متن کامل

Comparison of performance of various sphygmomanometers with intra-arterial blood-pressure readings.

Seven types of sphygmomanometer were used in random order on each of nine hypertensive patients and the readings compared with simultaneous intra-arterial blood-pressure recordings. All the devices gave significantly different values for systolic pressure, and only two measured diastolic pressure without significant error. Systolic pressure was consistently underestimated (range 31-7 mm Hg), an...

متن کامل

Using Hawksley random zero sphygmomanometer as a gold standard may result in misleading conclusions.

We combined a database of paired blood pressure measurements taken using the Hawksley random-zero sphygmonanometer and a standard mercury sphygmomanometer and a database of paired measurements made on a SpaceLabs 90202 ambulatory blood pressure recorder and standard sphygmomanometer to determine how the SpaceLabs 90202 would have fared if it had been assessed against the Hawksley random-zero sp...

متن کامل

Field evaluation of the Copal UA-231 automatic sphygmomanometer.

Automated sphygmomanometers should be evaluated in field studies before being recommended for epidemiological use. In this study an automated sphygmomanometer, the Copal UA-231, was evaluated on the basis of duplicate blood pressure measurements, one with this machine and one with a Hawksley random zero machine, taken on 1536 participants in a health survey. The Copal-random zero differences ha...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Hypertension

دوره 11 3  شماره 

صفحات  -

تاریخ انتشار 1988