Is the physical decay correction of the (18)F-FDG input function in dynamic PET imaging justified?
نویسندگان
چکیده
UNLABELLED In this theoretic note, the rationale for the physical decay correction of the (18)F-FDG input function in dynamic PET is investigated, using the Patlak equation as an example. METHODS The Patlak equation conventionally obtained when correcting the (18)F-FDG input function and correcting the tissue activity measurement for (18)F physical decay can also be derived from a 2-compartment analysis that does not conceptually involve any physical decay correction of the (18)F-FDG input function but accounts only for the physical decay of the trapped tracer. RESULTS We demonstrate that exactly the same equation can be derived from the 2 conceptual approaches, and hence each approach yields the correct uptake rate of the tracer. CONCLUSION No advantage in (18)F-FDG dynamic PET can be expected from using the concept of uncorrected data rather than that of decay-corrected data. Nevertheless, conceptually, we show that correcting the (18)F-FDG input function for radioactive decay cannot be justified and that this correction is not compatible with the calculation of patient radiation dose.
منابع مشابه
Factors influencing the pattern and intensity of myocardial 18F-FDG uptake in oncologic PET-CT imaging
Introduction:Myocardial 18F-FDG uptake is highly variable in oncologic whole body 18F-FDG PET/CT studies, ranging from quite intense to minimal distribution. Intense or heterogeneous myocardial 18F-FDG uptake is undesirable as it may interfere with the visual or quantitative evaluation of tumoral invasion and metastases in pericardium, myocardiu...
متن کاملF-18 FDG PET/CT Imaging of Eccrine Sweat Gland Carcinoma of the Scrotum with Extensive Regional and Distant Metastases
Eccrine carcinoma is an extremely rare malignant skin cancer arising from eccrine sweat glands with a high metastatic potential. It mainly occurs in the elderly, with equal incidence in both sexes. It usually spreads to regional lymph nodes, with liver, lungs, and bones being the most common sites of distant metastasis. Because of tumor rarity, little is known about the value of F18- FDG PET/CT...
متن کاملThe diagnostic difference between 18F- FDG PET and 99mTc-HMPAO SPECT perfusion imaging in assessment of Alzheimer's disease
Introduction:Brain imaging with F-18 fluorodeoxyglucose (18F-FDG) positron emission tomography or Tc-99m hexamethylpropyleneamine oxime (99mTc-HMPAO) SPECT is widely used for the evaluation of Alzheimer's dementia (AD); we aim to assess superiority of one method over the other. Methods: Twenty four patients with clinical diagnosi...
متن کاملDiagnostic performance of 18F-FDG PET-CT in patients presenting with secondary neck nodes from an unknown primary
Introduction: Clinical examination and even anatomical imaging may fail to identify primary site of malignancy in patients presenting with cervical nodal metastasis. 18F-Fluorodeoxyglucose Positron Emission Computed Tomography (18F-FDG PET-CT) is known to overcome the limitations of anatomic imaging. Methods: Sixty-three (63) patient...
متن کاملF-18 FDG PET/CT imaging of primary hepatic neuroendocrine tumor
Primary hepatic neuroendocrine tumors (PHNETs) are extremely rare neoplasms. Herein, we report a case of a 70-year-old man with a hepatic mass. The non-contrast computed tomography (CT) image showed a low-density mass, and dynamic CT images indicated the enhancement of the mass in the arterial phase and early washout in the late phase. F18- fluorodeoxyglucose (18F-FDG) positron emission tomogra...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine technology
دوره 37 2 شماره
صفحات -
تاریخ انتشار 2009