Diagnostic performance of coronary angiography by 64-row CT.

نویسندگان

  • Julie M Miller
  • Carlos E Rochitte
  • Marc Dewey
  • Armin Arbab-Zadeh
  • Hiroyuki Niinuma
  • Ilan Gottlieb
  • Narinder Paul
  • Melvin E Clouse
  • Edward P Shapiro
  • John Hoe
  • Albert C Lardo
  • David E Bush
  • Albert de Roos
  • Christopher Cox
  • Jeffery Brinker
  • João A C Lima
چکیده

BACKGROUND The accuracy of multidetector computed tomographic (CT) angiography involving 64 detectors has not been well established. METHODS We conducted a multicenter study to examine the accuracy of 64-row, 0.5-mm multidetector CT angiography as compared with conventional coronary angiography in patients with suspected coronary artery disease. Nine centers enrolled patients who underwent calcium scoring and multidetector CT angiography before conventional coronary angiography. In 291 patients with calcium scores of 600 or less, segments 1.5 mm or more in diameter were analyzed by means of CT and conventional angiography at independent core laboratories. Stenoses of 50% or more were considered obstructive. The area under the receiver-operating-characteristic curve (AUC) was used to evaluate diagnostic accuracy relative to that of conventional angiography and subsequent revascularization status, whereas disease severity was assessed with the use of the modified Duke Coronary Artery Disease Index. RESULTS A total of 56% of patients had obstructive coronary artery disease. The patient-based diagnostic accuracy of quantitative CT angiography for detecting or ruling out stenoses of 50% or more according to conventional angiography revealed an AUC of 0.93 (95% confidence interval [CI], 0.90 to 0.96), with a sensitivity of 85% (95% CI, 79 to 90), a specificity of 90% (95% CI, 83 to 94), a positive predictive value of 91% (95% CI, 86 to 95), and a negative predictive value of 83% (95% CI, 75 to 89). CT angiography was similar to conventional angiography in its ability to identify patients who subsequently underwent revascularization: the AUC was 0.84 (95% CI, 0.79 to 0.88) for multidetector CT angiography and 0.82 (95% CI, 0.77 to 0.86) for conventional angiography. A per-vessel analysis of 866 vessels yielded an AUC of 0.91 (95% CI, 0.88 to 0.93). Disease severity ascertained by CT and conventional angiography was well correlated (r=0.81; 95% CI, 0.76 to 0.84). Two patients had important reactions to contrast medium after CT angiography. CONCLUSIONS Multidetector CT angiography accurately identifies the presence and severity of obstructive coronary artery disease and subsequent revascularization in symptomatic patients. The negative and positive predictive values indicate that multidetector CT angiography cannot replace conventional coronary angiography at present. (ClinicalTrials.gov number, NCT00738218.)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnostic performance of 64-row coronary CT angiography in detecting significant stenosis as compared with conventional invasive coronary angiography

BACKGROUND The aim of the present study is to evaluate the accuracy of 64-multidetector-row computed tomography angiography (CTA) in comparison to conventional invasive angiography (CIA) in the diagnosis of significant stenosis (≥ 50%) of coronary artery tree. METHODS Assessment of CTA in the detection of coronary artery disease (CAD) was performed in patients referred because of symptoms or ...

متن کامل

Unusual Coronary Artery Fistula: Left Anterior Descending Coronary Artery - Left Ventricular Fistula Diagnosed by ECG-Gated Multi- Detector Row Coronary CT Angiography

medical conditions and in most cases, are found incidentally (1-7). Although the majority of cases are asymptomatic, some may cause coronary steal. For several decades, the conventional coronary angiography has been the best diagnostic modality for identifying coronary artery fistulas. However, with recent advances, the coronary angiography was replaced by the development of an electrocardiogra...

متن کامل

Giant aneurysm of the right sinus of Valsalva causing right ventricular outflow obstruction.

Validation of a new contrast material protocol adapted to body surface area for optimized low-dose CT coronary angiography with prospective ECG-triggering. Int J Cardiovasc Imaging 2010;26:591–7. 13. Tatsugami F, Husmann L, Herzog BA, Burkhard N, Valenta I, Gaemperli O et al. Evaluation of a body mass index-adapted protocol for low-dose 64-MDCT coronary angiography with prospective ECG triggeri...

متن کامل

Noninvasive visualization of coronary artery bypass grafts using 16-detector row computed tomography.

OBJECTIVES The aim of this study was to evaluate the diagnostic accuracy of a 16-detector row computed tomography (CT) scanner for the assessment of coronary artery bypass grafts. BACKGROUND A new generation of multislice spiral CT scanners, equipped with more and thinner detector rows, allows for reliable noninvasive detection of obstructive coronary artery disease. METHODS The study inclu...

متن کامل

Accuracy of MSCT Coronary Angiography with 64 Row CT Scanner—Facing the Facts

Improvements in multislice computed tomography (MSCT) angiography of the coronary vessels have enabled the minimally invasive detection of coronary artery stenoses, while quantitative coronary angiography (QCA) is the accepted reference standard for evaluation thereof. Sixteen-slice MSCT showed promising diagnostic accuracy in detecting coronary artery stenoses haemodynamically and the subseque...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The New England journal of medicine

دوره 359 22  شماره 

صفحات  -

تاریخ انتشار 2008