How accurate is anatomic limb alignment in predicting mechanical limb alignment after total knee arthroplasty?
نویسندگان
چکیده
BACKGROUND Anatomic limb alignment often differs from mechanical limb alignment after total knee arthroplasty (TKA). We sought to assess the accuracy, specificity, and sensitivity for each of three commonly used ranges for anatomic limb alignment (3-9°, 5-10° and 2-10°) in predicting an acceptable range (neutral ± 3°) for mechanical limb alignment after TKA. We also assessed whether the accuracy of anatomic limb alignment was affected by anatomic variation. METHODS This retrospective study included 314 primary TKAs. The alignment of the limb was measured with both anatomic and mechanical methods of measurement. We also measured anatomic variation, including the femoral bowing angle, tibial bowing angle, and neck-shaft angle of the femur. All angles were measured on the same full-length standing anteroposterior radiographs. The accuracy, specificity, and sensitivity for each range of anatomic limb alignment were calculated and compared using mechanical limb alignment as the reference standard. The associations between the accuracy of anatomic limb alignment and anatomic variation were also determined. RESULTS The range of 2-10° for anatomic limb alignment showed the highest accuracy, but it was only 73 % (3-9°, 65 %; 5-10°, 67 %). The specificity of the 2-10° range was 81 %, which was higher than that of the other ranges (3-9°, 69 %; 5-10°, 67 %). However, the sensitivity of the 2-10° range to predict varus malalignment was only 16 % (3-9°, 35 %; 5-10°, 68 %). In addition, the sensitivity of the 2-10° range to predict valgus malalignment was only 43 % (3-9°, 71 %; 5-10°, 43 %). The accuracy of anatomical limb alignment was lower for knees with greater femoral (odds ratio = 1.2) and tibial (odds ratio = 1.2) bowing. CONCLUSIONS Anatomic limb alignment did not accurately predict mechanical limb alignment after TKA, and its accuracy was affected by anatomic variation. Thus, alignment after TKA should be assessed by measuring mechanical alignment rather than anatomic alignment.
منابع مشابه
The Effect of Sagittal Femoral Bowing on the Femoral Component Position in Total Knee Arthroplasty
Background: In the current study, we investigated that how sagittal femoral bowing can affect the sagittal alignment ofthe femoral component in total knee arthroplasty (TKA).Methods: There were 25 patients underwent TKA. Long leg radiography in lateral view was performed. The sagittalfemoral bowing (SFB) and component alignment in relation to the sagittal mechanical axis and distal anterior cor...
متن کاملReliability of the hip-to-ankle radiograph in determining the knee and implant alignment after total knee arthroplasty.
Hip-to-ankle radiographs have been used to evaluate lower limb alignment before and after total knee arthroplasty. However, earlier studies have inappropriately used correlation to assess the reproducibility of the radiographs. We determined the reliability of the hip-to-ankle radiograph using the Bland-Altman analysis. Two consecutive hip-to-ankle radiographs were obtained in 52 patients (52 k...
متن کاملDoes patient perception of alignment affect total knee arthroplasty outcome?
OBJECTIVE This study was designed to address a recurring observation in our centre that, despite a satisfactory postoperative radiographic limb alignment, some patients are dissatisfied with the alignment and appearance of their operated leg. We carried out a prospective survey to determine patient perception of limb alignment after total knee arthroplasty (TKA) and whether level of satisfactio...
متن کاملComparison of Clinical, Functional, and Radiological Outcomes of Total Knee Arthroplasty Using Conventional and Patient-Specific Instrumentation
Background: Recently, patient-specific instrumentation (PSI) systems have been developed in order to increase theaccuracy of component positioning during total knee arthroplasty (TKA); however, the findings of previous studies arecontroversial in this regard. In the current randomized clinical study, the outcomes of computer tomography (CT)-basedPS (patient specific)-guided TK...
متن کاملCoronal Alignment of the Lower Limb and the Incidence of Constitutional Varus Knee in Korean Females
PURPOSE In total knee arthroplasty (TKA), it is important to restore neutral mechanical alignment. The purpose of this study was to assess whether the lower limb alignment is neutral in healthy Korean females and investigate the incidence of constitutional varus knees among them. MATERIALS AND METHODS Weight-bearing full-leg standing radiographs were obtained from 118 healthy females between ...
متن کامل