Phonocardiographic diagnosis of aortic ball variance.
نویسندگان
چکیده
Fatty infiltration causing changes in the silastic poppet of the Model 1000 series Starr-Edwards aortic valve prostheses (ball variance) has been detected with increasing frequency and can result in sudden death. Phonocardiograms were recorded on 12 patients with ball variance confirmed by operation and of 31 controls. Ten of the 12 patients with ball variance were distinguished from the controls by an aortic opening sound (AO) less than half as intense as the aortic closure sound (AC) at the second right intercostal space (AO/AC ratio less than 0.5). Both AO and AC were decreased in two patients with ball variance, with the loss of the characteristic high frequency and amplitude of these sounds. The only patient having a diminished AO/AC ratio (0.42) without ball variance at reoperation had a clot extending over the aortic valve struts. The phonocardiographic findings have been the most reliable objective evidence of ball variance in patients with Starr-Edwards aortic prosthesis of the Model 1000 series.
منابع مشابه
Phonocardiographic method of assessing changes in left ventricular function after Starr-Edwards replacement of aortic valve.
A phonocardiographic method is described for measuring the time taken by the ball of a Starr-Edwards prosthesis to move to the apex of the cage at the onset of left ventricular ejection, and from this its acceleration can be derived. The acceleration is conspicuously increased in post-ectopic beats and in exercise, but is unaffected by posture and tachycardia induced by atropine or ventricular ...
متن کاملImpaired function of cloth-covered Starr-Edwards mitral valve prosthesis. Detection by phonocardiography.
was suspected because of phonocardiographic abnormalities. A prolonged interval from aortic closure to opening of the mitral ball suggested an impediment to movement of the ball. This was confirmed by catheterization and cinefluorography. At autopsy the impaired ball movement was found to be due to thrombus buildup on the outflow face of the mitral valve orifice. It is suggested that frequent p...
متن کاملSound spectrographic diagnosis of aortic ball variance.
Abnormalities in the silastic poppets of cardiac valve prostheses have been detected with increasing frequency. Ball variance can cause serious mechanical dysfunction of the prosthesis and can result in sudden death. Contour sound spectrograms were recorded on 12 patients with ball variance confirmed by operation and 25 controls. In ball variance the frequency of the aortic opening sound at the...
متن کاملTraumatic hemolysis with hemoglobinuria due to ball variance.
P OSTIMPLANTATION ALTERATION of the physicochemical properties of the silastic poppet ( ball variance ) has been reported in some patients with aortic ball valve prostheses.12 Clinical recognition of this situation is difficult, and the diagnosis is usually made at autopsy. This report concerns a patient with ball variance manifested primarily by traumatic intravascular hemolysis and hemoglobin...
متن کاملPhonocardiographic manifestations of heterograft valve dysfunction in the mitral area.
Phonocardiographic and pathological features of mitral porcine aortic heterograft valve failure are described in 1o patients with rheumatic valvular disease. Six had isolated mitralporcine aortic heterograft valve; 3 also had one in the aortic area; one had this in both mitral and tricuspid areas with an aortic ball valve prosthesis. Allpatients had systolic murmurs at the apex indicative of mi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 38 1 شماره
صفحات -
تاریخ انتشار 1968