Diagnostic Usefulness of Transcutaneous Bilirubinometry in Very Preterm Newborns
نویسندگان
چکیده
BACKGROUND This study was performed to find out whether transcutaneous bilirubinometry could be a valid screening method for hyperbilirubinemia in preterm infants, especially for those who needed mechanical ventilation. METHODS We evaluated 63 preterm Iranian newborns who were managed in the neonatal intensive care unit of Shahidbeheshti University Hospital, Isfahan, Iran from April 2009 to April 2010. Transcutaneous bilirubin (TCB) measurements were obtained using BiliCheck(™) shortly before or 10 minutes after taking blood for determination of the plasma bilirubin level in premature newborns, who did not receive phototherapy. We assessed the correlation between the transcutaneous bilirubin and plasma bilirubin level by linear regression analysis. We also analyzed the gestational age, birth weight, postnatal age, sex, and hematocrit, for determination of their effect on transcutaneous bilirubin accuracy. RESULTS The overall bilirubin concentration ranged from 5.4 to 17 mg/dL and from 4.8 to 17.3 mg/dl for total serum bilirubin (TSB) and transcutaneous bilirubin, respectively. The mean values obtained by transcutaneous bilirubinometry were slightly higher than the total TSB values. The correlation coefficient between TSB and TCB was r=0.82, P<0.001, and this was not influenced by gestational age, postnatal age or hematocrit, which were previously considered to be important. The correlation coefficient between TSB and TCB in mechanically ventilated preterm infants was r=0.75, P<0.001. CONCLUSION Plasma bilirubin level can be accurately measured by BiliCheck(™) in premature newborns, even in newborns who need mechanical ventilation.
منابع مشابه
Evaluation of transcutaneous bilirubinometry in preterm infants of gestational age 32-34 weeks.
AIMS The aim of this prospective study was to evaluate the accuracy of transcutaneous bilirubinometry using the Minolta Air-Shields JM-103 device in preterm newborns of gestational age 32-34 weeks, and to identify the most appropriate measurement site. METHODS Transcutaneous bilirubin (TcB) measurements were performed over forehead, sternum and abdomen, if total serum bilirubin (TSB) had to b...
متن کاملTranscutaneous bilirubinometry in preterm neonates.
This prospective study was conducted to evaluate the accuracy of transcutaneous bilirubinometry in preterm newborns less than 32 weeks of gestation. Serum bilirubin values measured by direct spectrophotometry were considered as standard, the range was 2.2-12.5 mg/dL. 32 jaundiced infants of less than 32 weeks of gestation without phototherapy, including 10 ELBW neonates, were enrolled. Close co...
متن کاملTranscutaneous Bilirubinometry in Preterm and Term Newborn Infants before and during Phototherapy.
INTRODUCTION To evaluate the accuracy of transcutaneous bilirubin measurement in a large population of newborn infants, before and during the phototherapy. PATIENTS AND METHODS A single Bilicheck instrument was used for transcutaneous measurements. A photo-opaque patch was positioned over the measurement site prior to starting phototherapy. Transcutaneous bilirubinometry was conducted on an u...
متن کاملTranscutaneous bilirubinometry in Pakistani newborns: a preliminary report.
Neonatal hyperbilirubinemia is a frequently encountered problem in the neonatal period and carries a potential risk of encephalopathy. Early detection and quantification is important, and transcutaneous bilirubinometry (TcB) has been recommended as a non-invasive method for rapid screening. We prospectively compared the efficacy of TcB in 65 normal Pakistani jaundiced newborns undergoing simult...
متن کاملApplication of transcutaneous bilirubinometry for screening of neonates with significant hyperbilirubinemia in the city of Kerman
In order to screen for neonatal significant hyperbilirubinemia,a propective cross sectional study was carried out on 343 full-term neonates taken to investigator in Kerman between October 1995 and july 1996.there was a linear correlation between serum bilirubin and transcutaneous bilirubinometri (r=0.85,standard error=0.004).sensitivity and specificity of this method were 95% and 84% respective...
متن کامل