Utility of untimed single urine protein/creatinine ratio as a substitute for 24-h proteinuria for assessment of proteinuria in systemic lupus erythematosus.

نویسندگان

  • Jorge Medina-Rosas
  • Dafna D Gladman
  • Jiandong Su
  • Arthy Sabapathy
  • Murray B Urowitz
  • Zahi Touma
چکیده

INTRODUCTION In this study, we determined: (1) the utility of an untimed sample of urine protein/creatinine ratio (PCR) as a screening test for proteinuria, (2) its ability to accurately measure proteinuria, and (3) cutoff values for PCR predicting protein content in a 24-h urine collection sample (24hP) of 0.5, 1.0, and 2.0 g/day. METHODS Analysis was performed on data from a single lupus cohort (2008-2014). Proteinuria was measured in a 24hP and with PCR. On the basis of 24hP, samples were divided into 4 groups: group 1, <0.5 g/day; group 2, 0.5-0.99 g/day; group 3, 1-1.99 g/day; and group 4, ≥2 g/day. To determine the validity of PCR in screening for proteinuria, the Pearson correlation coefficient was determined for the urine samples with normal PCR (<0.05 g/mmol) and normal 24hP (<0.5 g/day). The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of PCR were calculated. To determine the ability of PCR to accurately measure the level of proteinuria, in addition to the correlation between 24hP and PCR, agreement was determined by intraclass correlation coefficient, concordance correlation coefficient, and Bland-Altman plot between 24hP/24hC and PCR. The best cutoffs for PCR predicting a 24hP of 0.5, 1.0, and 2.0 g/day were determined with the receiver operating characteristic curve. RESULTS The correlation of the samples with normal PCR as well as 24hP (n = 552) was 0.29 (p < 0.0001). PCR sensitivity and specificity against 24hP were 91 % and 83 %, respectively. The PPV was 82.5 %, and the NPV was 91.4 %. The correlation for all samples (n = 1233) was high, but low to moderate for groups 1, 2, 3, and 4. The agreement for all samples was appropriate but poor for groups 1, 2, 3, and 4. PCR cutoffs for 24hP of 0.5, 1.0, and 2.0 g/day were 0.08, 0.16, and 0.35 g/mmol, respectively. CONCLUSIONS PCR can be used as a screening test for proteinuria, and the best cutoff value to predict a 24hP of 0.5 g/day is 0.08 g/mmol (800 mg/g). The accurate level of proteinuria should be measured by the gold standard test, 24hP.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantification of Proteinuria with Urinary Protein to Osmolality Ratios in Children

Background: The ratio of urine protein to urine osmolality has recently been suggested as an accurate method to determine proteinuria.  Objective: We studied the correlation of urine protein to urine osmolality ratio with 24-hr urinary protein excretion. Methods: 150 children aged 0.11–17 years admitted to the Department of Pediatric Nephrology were included in this study. Early morning urine s...

متن کامل

Random spot urine protein/creatinine ratio: a reliable method for monitoring lupus nephritis?

BACKGROUND Lupus nephritis (LN) is a common and severe manifestation of systemic lupus erythematosus (SLE) that can lead to end-stage renal disease. According to the Kidney Disease Outcomes Global Improving clinical Guidelines for Glomerulonephritis, spot urine protein/creatinine (P/C) ratio should be used for monitoring LN. However, some reports write that the random spot urine P/C ratio is un...

متن کامل

Urine protein-to-creatinine ratio in an untimed urine collection is a reliable measure of proteinuria in lupus nephritis.

OBJECTIVE To evaluate the accuracy of urine protein-to-creatinine (P/C) ratio in an untimed urine specimen as compared with 24 h total protein excretion for measurement of proteinuria in patients with lupus nephritis. METHODS Proteinuria in patients with lupus nephritis was assessed by 24 h total protein excretion and spot urine P/C ratio. Correlation and limits of agreement between the two m...

متن کامل

Relationship between albuminuria and total proteinuria in systemic lupus erythematosus nephritis: diagnostic and therapeutic implications.

BACKGROUND AND OBJECTIVES Albuminuria is regarded a sensitive measure of progression of glomerular disease. This study was undertaken in patients who had systemic lupus erythematosus glomerulonephritis (n = 57) and were followed in the Ohio SLE Study to determine whether measuring albuminuria offered clinical advantages over that of total proteinuria. DESIGN, SETTING, PARTICIPANTS, & MEASUREM...

متن کامل

Random spot urine protein/creatinine ratio is unreliable for estimating 24-hour proteinuria in individual systemic lupus erythematosus nephritis patients.

BACKGROUND Recently the American Rheumatologic Association (ARA) recommended random spot urine protein/creatinine ratio (P/C) to monitor systemic lupus erythematosus (SLE) glomerulonephritis (GN). Shortly afterward, 2 works were published, designated Study 1 and Study 2, which are the only studies to test spot P/C in SLE GN. Here we evaluate Study 1 and Study 2, which came to different conclusi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Arthritis research & therapy

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2015