The particle flow approach requires calorimeters with ultra-high granularity. The design of the Si/W ECAL has thus been based on this principle. It is composed of 30 layers, each layer having an array of 3 × 3 silicon matrices. These matrices or wafers are divided into 6 × 6 cells with an area of 1 cm. The mechanical structure consists of tungsten plates wrapped in carbon fiber, creating 15 alveolas into which so-called slabs are inserted. These slabs consist of one layer of tungsten between two layers of silicon wafers and their corresponding PCBs. The prototype is divided into three stacks, each consisting of 10 layers but with different thicknesses of the passive layers. The overall thickness is about 20 cm, corresponding to 24 X0. A detailed description of all the technical and comissioning aspects can be found in a dedicated paper [3].

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CALICE Si/W electromagnetic calorimeter prototype, first testbeam results

A highly granular electromagnetic calorimeter prototype based on tungsten absorber and sampling units equipped with silicon pads as sensitive devices for signal collection is under construction. The full prototype will have in total 30 layers and be read out by about 10000 Si cells of 1 × 1 cm. A first module consisting of 14 layers and depth of 7.2 X0 at normal incidence, having in total 3024 ...

متن کامل

Analyses of test beam data using the CALICE calorimeter

We discuss several features of hadronic showers recorded in the high granularity CALICE Si-W ECAL and scintillator-tile HCAL and confront them with several Geant4 physics models. The first measurements of the time-structure of hadronic showers in a tungsten scintillator calorimeter are presented. The high granularity of the CALICE calorimeters allows a software compensation which improves the e...

متن کامل

Calice Electromagnetic Calorimeter Readout Status

The CALICE Electromagnetic CALorimeter (ECAL) will be a silicon-tungsten sampling calorimeter [1] with 30 layers of silicon wafers, each containing an 18×18 array of diode pads, giving 9720 channels to be read out. The signal from each pad is amplified by a Very Front End (VFE) ASIC [2] which multiplexes the signals from 18 pads onto one output line. The silicon wafers and VFE chips are mounted...

متن کامل

s . in s - de t ] 1 1 Ju n 20 14 Performance of the first prototype of the CALICE scintillator strip electromagnetic calorimeter The CALICE Collaboration

A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45×10×3 mm plastic scintillator strips. Data were collected using a positron test beam at DESY with momenta between 1 and 6 GeV/c. The prototype’s performance is presented in terms of the linearity and resolution of the energy

متن کامل

Prototype Calorimeters for Linear Collider Detectors

For several years, CALICE has been testing highly granular calorimeter prototypes using analogue readout. These devices are envisaged for particle flow [1] application in a future linear collider detector. A novel alternative, especially interesting for the hadron calorimeter, is to use a simplified digital (= 1 – bit) readout coupled with very small cell sizes. In the past year the first large...

متن کامل

Hadronic showers in the CALICE calorimeter prototypes

The CALICE collaboration has constructed highly granular electromagnetic and hadronic calorimeter prototypes to evaluate technologies for the use in detector systems at the future International Linear Collider. These calorimeters have been tested extensively in particle beams at CERN and at Fermilab. We present preliminary results of an analysis of hadronic events in the combined system under t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009