Induced radioactive nuclides of 10-MeV radiotherapy accelerators detected by using a portable HP-Ge survey meter.

نویسندگان

  • Toshioh Fujibuchi
  • Satoshi Obara
  • Ichiro Yamaguchi
  • Masaya Oyama
  • Hiroshi Watanabe
  • Takeji Sakae
  • Kazuaki Katoh
چکیده

The radioactivation of linear accelerator components for radiation therapy is interest for radiation protection in general, and particularly, when decommissioning these structures. The energy spectra of gamma rays emitted from the heads of two accelerator models, EXL-15SP and Clinac iX, after 10-MeV X-ray irradiation, were measured using a high-purity germanium semiconductor survey meter. After spectrum analyses, activities of (24)Na, (28)Al, (54)Mn, (56)Mn, (57)Ni, (58)Co, (60)Co, (64)Cu, (65)Zn, (122)Sb, (124)Sb, (181)W, (187)W, (196)Au, and (198)Au were detected. One centimetre deep dose-equivalent rate of the heads of the linear accelerator was measured using the survey meter. The dose rate decreased to ∼10 % of its initial rate after 1 week. Long-term activations were few, the radioactivity level was low, and a cooling time of several days was effective for reducing dose rate to an acceptable level for decommissioning.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radioactive Airborne Species Formed in the Air in High Energy Accelerator Tunnels

High-power and high-energy proton accelerators have been proposed for basic scientific research in several countries, and some of them are under construction. In Japan, the high intensity proton accelerator (J-PARC), consisting of a 200-MeV Linac as well as 3-GeV and 50-GeV synchrotrons, of which the maximum beam power is about 1MW, is to be completed at the end of 2007. This accelerator was de...

متن کامل

Secondary Particles Produced by Hadron Therapy

Introduction Use of hadron therapy as an advanced radiotherapy technique is increasing. In this method, secondary particles are produced through primary beam interactions with the beam-transport system and the patient’s body. In this study, Monte Carlo simulations were employed to determine the dose of produced secondary particles, particularly neutrons during treatment. Materials and Methods I...

متن کامل

Small plasma focus as neutron pulsed source for nuclides identification.

In this paper, we present preliminary results on the feasibility of employing a low energy (2 kJ, 31 kV) plasma focus device as a portable source of pulsed neutron beams (2.45 MeV) generated by nuclear fusion reactions D-D, for the "in situ" analysis of substances by nuclear activation. This source has the relevant advantage of being pulsed at requirement, transportable, not permanently radioac...

متن کامل

The dosimetry assessment of Varian Linear Accelerators of 6, 15 and 20 MV by Monte Carlo Method

 Introduction: Monte Carlo method is often applied in radiation therapy as utilized in all the branches of science. An important requirement for successful radiotherapy is carefully examine the dose distribution specifications and decrease the difference between these features with experience to an acceptable level. In this study, the characteristics of 6, 15 and 20 MeV incident x-rays are prov...

متن کامل

Continuous Measurement of Environmental Gamma Radiation in Tokyo Using Ge Semiconductor Detector

INTRODUCTION Radon and its progeny are natural radioactive nuclides and exist in various places on the earth. Some of the radon progeny in air and clouds is transferred into rainwater. It has often been observed that gamma radiation at ground level increases on a rainy day. The increase of natural background gamma radiation disturbs the estimates of the influence of artificial radioactive nucli...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiation protection dosimetry

دوره 148 2  شماره 

صفحات  -

تاریخ انتشار 2012